background image

13

GB

Electrical connection / Power supply

The power is supplied via the 24 V mains power adapter provided.

NOTE

Note the information given on the 24 V mains power adapter’s type plate. It gives all the information
necessary for connecting the drive.

Assignment of the connecting

cable on the 24 V mains power

adapter

Assignment of the connecting

cable on the drive

The polarity of the power unit cable is shown by a marking:

Wire

Polarity

Drive cable

not marked

= + 24 V

green (5)

marked

= GND (ground)

brown (1)

+ 12 V 

 output (power supply for motion detector and sensor)

The drive has a + 12 V output for connecting external sensors and motion detectors.

Colour assignment of the drive cable for the + 12 V 

 output

Drive cable

Assignment

pink (6)

= + 12 V 

 output (max. 70 mA)

grey (2)

= GND (ground)

Содержание RolloSystems T2

Страница 1: ...GB Operating instructions for RolloSystems T2 VBD 509 1 GB 09 09 Article No RS T2 80...

Страница 2: ...confidence The RolloSystems T2 has been developed with the greatest possible convenience in mind Having applied uncompromising quality standards and carried out thorough testing we are proud to be abl...

Страница 3: ...on 22 Starting automatic end point search 23 Reversing the running direction 24 Setting the braking distance 25 Setting the sensitivity of obstacle detection 26 Setting speeds automatically and manual...

Страница 4: ...1 2 3 4 8 5 6 7 10 General view Legend 1 Plus key 2 OK OK key 3 Minus key 4 Toothed belt wheel 5 Assembly block 6 Toothed belt wheel cover 7 Operating panel lid 8 LED display 9 Connecting cable 10 Ty...

Страница 5: ...2 80 i 1 2 3 4 5 6 After unpacking the product compare the contents of the package with this list 1 x Drive 1 x Operating instructions 1 x Operating panel lid 1 x Toothed belt wheel cover 1 x 24 V mai...

Страница 6: ...door or sliding shutter fittings must correspond to DIN 1527 load class 6 length of useful life and load class 3 initial friction Permissible sliding doors sliding shutters i Operating conditions i An...

Страница 7: ...e doors that are subject to building inspectorate specifications Fire doors Smoke control doors Escape doors Doors in escape routes etc Incorrect assembly may lead to risk of injury The manufacturer i...

Страница 8: ...he range of motion of the sliding door sliding shutter during operation Incorrect use leads to an increased risk of injury Never reach into moving sliding doors sliding shutters or into actuated compo...

Страница 9: ...tart and before the end point is reached the drive switches to soft stop so that the movement ends slowly Safety functions An obstacle detection function monitors the movement of the sliding door slid...

Страница 10: ...cle detection sensor may incorrectly identify an obstacle in which case proceed as detailed on page 42 Functional description Manual decoupling i The RolloSystems T2 has a manual decoupling function I...

Страница 11: ...justable obstacle detection sensitivity Adjustable speeds for opening and closing Adjustable automatic closing Integral receiver for manual transmitter 433 Mhz Keeloq and radio motion detector Adjusta...

Страница 12: ...hanism is in perfect mechanical working order It should be possible to open and close the sliding door or sliding shutter easily Check the weight of the sliding unit The permissible total weight of 80...

Страница 13: ...on the 24 V mains power adapter Assignment of the connecting cable on the drive The polarity of the power unit cable is shown by a marking Wire Polarity Drive cable not marked 24 V green 5 marked GND...

Страница 14: ...see page 34 The function of each control input can be set as needed This is done in menus and The following functions can be set Off NC mode potential free opener contact NO mode potential free close...

Страница 15: ...this input the switch contacts in this mode must be switched in series Connecting a potential free closer contact as per 12 V NO mode pink 6 12 V Control input Potential free closer contact Setting m...

Страница 16: ...he drive stops Control inputs A and B must not both be set to mode and If the required application can be implemented using only one control input the second control input can be set to any other func...

Страница 17: ...Connecting two ArtMotion motion detectors in closer mode 24 V GND ArtMotion Power Supply Potential free output white white brown brown green green yellow yellow Cable green 5 brown 1 grey 2 white 3 o...

Страница 18: ...detector Parallel connection of two ArtMotion motion detectors in closer mode ArtMotion 1 ArtMotion 2 RolloSystems T2 green brown grey yellow or white 24 V GND ground Control input amarillo verde marr...

Страница 19: ...function Drive menu structure All necessary settings can be made in the drive control menu Functions are selected via the menu The following table gives a brief introduction to the individual functio...

Страница 20: ...on of control input A 3 4 5 Keys LED display Call up the menu Confirm the selection and switch to setting mode The display flashes Set the required function e g closer contact NC Return to menu Exit t...

Страница 21: ...eck the weight of the sliding unit max 80 kg 2 Assemble and connect the drive 3 Menu activate a manual transmitter optional 4 Menu activate the search run for the end points 5 Check the running direct...

Страница 22: ...he automatic reference run is a potential source of danger During the automatic reference runs the force limitation is not yet operational therefore it is important to ensure that no one is in the pat...

Страница 23: ...assoonasthedrivestartsup Thesearch always begins in an opening direction Cancel Find end point IMPORTANT If the end point search starts in a closing direction you should cancel the search run by repea...

Страница 24: ...ry movement of the door the direction of travel is shown in the LED display as follows Door travel direction LED display Opening open Also on the first search run to learn the end points Closing close...

Страница 25: ...r panel or shutter and the running performance NOTE If the sliding unit stops suddenly while braking then travels in the opposite direction the braking distance has been set incorrectly As too much fo...

Страница 26: ...nsitivity low sensitivity factory setting IMPORTANT When using the drive outside you should set the sensitivity low enough that frost and wind do not disrupt normal operation Call up the menu Select f...

Страница 27: ...th safety standards The speed is set at the factory so as to comply with the maximum forces for a sliding door or for a sliding shutter as set out in the relevant safety standards where the maximum we...

Страница 28: ...up the menu Select function Mounting type Confirm selection The current type of mounting is shown and flashes Set the required type of mounting The sliding unit runs into the wall The sliding unit is...

Страница 29: ...ed slow speed high speed Return to menu NOTE Subsequently the closing speed can be set in menu item 6 see page 30 Call up the menu Select function Mounting type Confirm selection The current speed is...

Страница 30: ...l selection of the opening speed has been activated it is also possible to manually set the closing speed IMPORTANT Repeating the end point search and reference runs Every time the closing speed is al...

Страница 31: ...matic closing time 3 seconds 6 seconds 10 seconds 15 seconds 21 seconds 28 seconds 37 seconds 48 seconds 60 seconds Function of control inputs in mode and when the Automatic closing function is activa...

Страница 32: ...the menu Select function Automatic closing Confirm selection The current status of the function the current closing time is shown and flashes e g Set the required closing time see table on page 31 or...

Страница 33: ...oor sliding shutter is fitted with a mechanical coupling this can be decoupled when the sliding unit is pushed before the drive recognises the manual movement In this case the Push mode does not funct...

Страница 34: ...ter switches Close dead man operation e g for roller shutter switches only potential free closer contacts for a roller shutter switch Brief description of functions Off The control input is switched o...

Страница 35: ...oved manually If function Automatic closing is active the sliding unit is closed approx 6 seconds after Pause mode is switched off 4 Open signal closer contact and 5 Close signal closer contact These...

Страница 36: ...1 or Setting the function of control inputs A and B OK OK OK Call up the menu Set the required function or Control inputs Confirm selection or The current status of the function is shown and flashes...

Страница 37: ...gs apply again see page 46 IMPORTANT After a reset has been carried out all settings must be entered again NOTE Press the OK key briefly to exit the function without performing a reset Call up the men...

Страница 38: ...io motion detector see the operating instructions for the respective radio motion detector Also refer to the installation and operating instructions for the radio motion detector Call up the menu Sele...

Страница 39: ...3 5 Press for two seconds 1 Activating deactivating a radio motion detector Keys LED display OK OK OK Call up the menu Select function Confirm selection The current status of the function is shown an...

Страница 40: ...conds 1 Call up the menu Select function Activate manual transmitter Confirm selection The number of manual transmitters activated flashes in the display No manual transmitter is yet activated Activat...

Страница 41: ...5 Activating deactivating a manual transmitter Keys LED display OK OK OK Call up the menu Select function Confirm selection The number of manual transmitters activated flashes in the display Deactiva...

Страница 42: ...e 23 Possible cause The sensitivity level for obstacle detection has been set too high Solution Reduce sensitivity level for obstacle detection see page 26 Possible cause The sliding unit is running j...

Страница 43: ...e displaced after a power failure in which case the end points have to be reset manually What happens if synchronisation has been unsuccessful If no end points have been located after the fourth synch...

Страница 44: ...t an automatic end point search see page 23 The drive is sticking movement is no longer possible The drive or the sensor electronics are defective Remedy Check the toothed belt Servicing required Erro...

Страница 45: ...le Automatic closing time adjustable Number of control inputs 2 A and B Safety functions Obstacle detection manual locking Connecting cable 6 x 0 34 mm2 LIYY length 2 m Protection type Drive IP55 Powe...

Страница 46: ...test level 3 IEC 61000 4 4 test level 3 IEC 61000 4 5 test level 3 IEC 61000 4 6 test level 3 IEC 61000 4 11 IEC 61000 4 13 test level 2 Reversal of running direction Off Automatic closing time Off Br...

Страница 47: ...ear External influences such as impacts knocks or weathering Repairs and modifications by third party unauthorised persons Use of unsuitable accessories Damage due to unauthorised electrical surges e...

Страница 48: ...errors Diagrams subject to change RADEMACHER Ger te Elektronik GmbH Co KG Buschkamp 7 46414 Rhede info rademacher de www rademacher de Service Telefon 01805 933171 service rademacher de 14 ct min aus...

Отзывы: