Chapter 5 - Troubleshooting
Terminal and COM Port Problems
140
Terminal and COM Port Problems
Symptom
Reason
Solution
Screen continuously
puts out garbage
characters.
The likely cause of this
problem is a baud rate
mismatch between the
terminal emulator and the
enclosure. The baud rate can
be set from 9,600 to 115,200.
1 Shut down the controller.
Refer to the software user’s guide.
2 Power down the enclosure.
3 For Hyper-Terminal:
a. Select the File menu and
choose Properties.
b. Click the Configure button.
c. Choose 9600 and click OK.
Nothing is displayed on
the terminal emulator
screen.
The probable cause of this
problem could be an incorrect
baud rate setting, a bad
RS-232 cable connection or an
incorrect cable type.
If the cable is properly connected,
ensure that the cable is a null modem
type.
Screen is updated, but
will not respond to
keystrokes.
Improper setting.
Disable hardware flow control on the
terminal or terminal emulator.
Содержание OmniStor 4900F Series
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 38: ...Chapter 1 Getting Started Audible Alarm 24...
Страница 58: ...Chapter 2 Topologies and Operating Modes Application of Availability 44...
Страница 128: ...Chapter 3 Setup and Installation Powering Off the Storage System 114...
Страница 156: ...Chapter 5 Troubleshooting Problems During Bootup 142...
Страница 178: ...Chapter 6 Maintenance Replacing the Enclosure 164...
Страница 182: ...Appendix A Technical Information Specifications 168...
Страница 196: ...Index 182...