Programming and Operation Using the Dash Buttons
15
Speedometer Calibration
The speedometer, odometer and trip odometer will not read correctly you perform the following calibration
procedure.
1) Turn on the dash and enter setup mode by entering a MED press on the
button.
2) Step through each setup parameter by entering a SHORT press on the
button until you reach
the
P8MI
parameter in the lower left LCD position.
3) Drive exactly 1/8 of mile (660 ft) and stop.
4) Enter a SHORT press on the
button to set the calibration factor.
5) Exit setup mode by entering a LONG press on the
button until the word
WAIT
is displayed
in the lower left LCD position. Make sure you do not turn the dash off until the word
WAIT
has
disappeared and the dash has reset.
Fuel Level Calibration
From the factory, the fuel level will read from 0 to 5000. If you would like the fuel level to read from 0 to
100 percent you must properly perform the following calibration procedure.
1) Empty the fuel tank to the level you wish to call %0.
2) Turn on the dash and enter setup mode by entering a MED press on the
button.
3) Step through each setup parameter by entering a SHORT press on the
button until you reach
the
FTLO
parameter in the lower left LCD position.
4) Enter a SHORT press on the
button to set the tanks emp ty value.
5) Enter a SHORT press on the
button to reach the next parameter
FTHI
.
6) Fill the fuel tank to the level you wish to call %100.
7) Enter a SHORT press on the
button to set the tanks full value.
8)
Exit setup mode by entering a LONG press on the
button until the word
WAIT
is displayed
in the lower left LCD position. Make sure you do not turn the dash off until the word
WAIT
has
disappeared and the dash has reset.