background image

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 
 
 

Race

pak

   

Ultra Dash

 

Installation and Operation Instructions 

300-DS-UDX6S 

Содержание Ultra Dash Xtreme

Страница 1: ...Racepak Ultra Dash Installation and Operation Instructions 300 DS UDX6S...

Страница 2: ......

Страница 3: ...g Wires from the Connector and or changing EGT Probes 7 Jack Shaft Sensor and Collar Installation 7 Remote Switch 8 External Battery 8 Installing V Net Channels 9 Programming and Operation Using the D...

Страница 4: ...r System 28 Configuring Record Parameters 29 Setting the Record Length 30 Setting the Record Enable Channel 30 Setting the Record Start Threshold 30 Sending the Record Parameters 31 Transferring Data...

Страница 5: ...dicator output Internal warning indicator light Internal high beam indicator light V Net port for expansion of up to 5 additional channels Ten minutes of record and playback memory Minimum and Maximum...

Страница 6: ...Introduction 2...

Страница 7: ...e thread lock or nylock nuts on the mounting studs Port Descriptions Connector Locations Port B Serial Port V Net Port Port A Port A Port A is used to connect the main power source warning indicator i...

Страница 8: ...er gauge output wire Pin 3 Not Used Pin 4 Premium Fuel Indicator Input Grounding the brown wire will cause the premium fuel indicator to activate Insert the brown wire in pin position 4 Connect the ot...

Страница 9: ...e switch in pin position 11 Alternately you can connect the black wire from the remote switch to a good chassis ground instead of running the wire back to pin 11 on the dash Pin 12 Jack shaft RPM and...

Страница 10: ...EGT 1 probe in pin position 3 Pin 4 External Battery Ground Connect this wire only if you plan to use an external DC battery to power the dash when the engine is not running Insert the black wire in...

Страница 11: ...e required if your current temperature switch uses a larger thread Make sure to use thread sealer when installing the sensor to prevent water leaks Removing Wires from the Connector and or changing EG...

Страница 12: ...external Ni Cad battery can be used to power the dash when the engine is not running and power is not available to the main power input at port A pin 13 When the engine is shut off or the main power...

Страница 13: ...the V Net extension cable in the V Net port Step 3 Plug the other end of the V Net cable in to the first V Net module You can install up to five V Net modules You can plug the V Net modules in any or...

Страница 14: ......

Страница 15: ...ctions depending on how long the button is held down In this manual we will refer to the three different button press types as SHORT MED and LONG To help determine when to release the button and as a...

Страница 16: ...se or decrease the parameter value in small increments A LONG press on the and buttons will increase or decrease the parameter value in large increments To exit setup mode enter a LONG press on the bu...

Страница 17: ...most snowmobiles 6 6 Swept tach engine rpm scale SCAL 0 11 500 rpm max 1 13 500 rpm max 0 7 Engine RPM rev warning REVL 0 20 000 RPM 8 500 8 Jack shaft sensor type R2TY 0 Magnet switch 1 Zero crossing...

Страница 18: ...dicator input value when ON PFON 0 input is grounded when ON 1 input has voltage when ON 0 20 Low oil level indicator input value when ON OLON 0 input is grounded when ON 1 input has voltage when ON 1...

Страница 19: ...evel Calibration From the factory the fuel level will read from 0 to 5000 If you would like the fuel level to read from 0 to 100 percent you must properly perform the following calibration procedure 1...

Страница 20: ...eedometer Upper Left Fuel Level Lower Left Water Temperature Lower Center Maximum Exhaust Gas Temperature Value and Cylinder Number DISPLAY 1 Lower Right Odometer Trip EGT 3 EGT 4 see note below Swept...

Страница 21: ...pm and engine jack shaft ratio are not Also if you have added any channels on the V Net port you can use scroll mode to view them The only way to view these channels is to enter scroll mode To enter s...

Страница 22: ...OT Water temperature VOLT External battery volts when running on external battery power Rectified volts when running on main AC DC power RAT Engine to jack shaft ratio Engine RPM divided by Jack Shaft...

Страница 23: ...arning indicators will be recorded After a recording you may playback the data on the dash or download it to our optional DataLink PC software Recorded data will remain in memory even if the dash is t...

Страница 24: ...lay in the lower left position on the LCD External warning light output see Wiring Port B All of the warning inputs do not activate all three warning indicator types Some only activate the alpha displ...

Страница 25: ...g a MED press on the button This will clear the warning only for that occurrence If the input that activated the warning falls below the warning limit and is later activated again the alpha warning wi...

Страница 26: ......

Страница 27: ...f you have purchased the PC download package you will need to insert the disk and click on the OK button If you have purchased the PC programming software then just click on the Demo Only button If yo...

Страница 28: ...ep is to connect your PC to your dash using the serial interface cable supplied with the DataLink software The next step is to start the DataLink program by clicking on the DataLink icon located on th...

Страница 29: ...channel After you have opened the car configuration file the next step in modifying the setup of your system is to select the device channel to be modified To select a device channel position the mous...

Страница 30: ...of sensor connected to the channel The following describes the basic sections of the edit dialog box and their locations Online Help Box The online help box is a scrollable text area containing detai...

Страница 31: ...age Device Programmed Successfully at the bottom of the massage log Select the OK button to exit the dialog box As a final step save the car configuration file to your disk by clicking on the save ico...

Страница 32: ...dash using the serial communication cable and power up your system Next select the ReadVNet Config selection located in the Editmain menu selection The DataLink software will now query the V Net modu...

Страница 33: ...o begin recording only after one of the monitored data channels exceeds a preset threshold For instance the logger can be programmed to begin recording any time the Engine RPM exceeds 3000 rpm Once th...

Страница 34: ...number of seconds to record Enter the new desired value in the edit box Setting the Record Enable Channel To program the record enable channel locate the Can ID for Record Enable channeloption and se...

Страница 35: ...he Record Parameters The final step in programming the record parameters on your dash is to send the configuration you just edited to from your PC to your dash over the serial communication cable To s...

Страница 36: ......

Страница 37: ...d you will be asked to select which configuration file to use Select the configuration file that contain VDash and your serial number as discussed the previous section The system will transfer the dat...

Страница 38: ...the Run Log sections that are user programmable to allow test information to be entered during the download process Fill out the information as appropriate The file save dialog box will then be displa...

Страница 39: ...Remember that only channels in the right hand list will be displayed during a real time telemetry session Next select the Real Time Sample Rate from the options list in the lower left hand corner of...

Страница 40: ...ct the Telemetry icon shown below or the New Telem Session menu item located in the File main menu selection A dialog box as shown below will be displayed and you will then be asked to select the conf...

Страница 41: ...u All previously recorded data will be erased from the file If you wish to save the data stop the data acquisition and use click the Save icon located in the tool bar or select Save located in the Fil...

Отзывы: