![Quantum SuperLoader 3A Series Скачать руководство пользователя страница 91](http://html.mh-extra.com/html/quantum/superloader-3a-series/superloader-3a-series_user-manual_770658091.webp)
Chapter 5 Troubleshooting
Returning the Autoloader for Service
Quantum SuperLoader 3A Series User’s Guide
77
Returning the Autoloader for Service
If you need to return the autoloader to the factory for service, first verify
which customer replaceable unit (CRU) that you need to return and
return only that CRU, not the entire autoloader.
Once you determine the CRU to replace, contact customer support to
obtain return authorization (RA) and shipping information. When you
have the RA number, use the following procedure.
Preparing the Autoloader
for Shipment
5
If you must return the complete autoloader for service, use these steps to
prepare the autoloader for shipment.
1
Remove all cartridges from the unit.
2
Power off the autoloader via the front panel.
3
Remove the power and Ethernet cables from the autoloader.
Removing the Autoloader
from a Rack
5
To remove the autoloader from a rack:
1
Loosen the four screws that connect the two support brackets to the
two autoloader brackets.
2
Loosen the four screws on the front of the autoloader that attach the
two front tabs (support brackets) to the front rails. Do not remove the
screws completely at this time.
3
Remove the four screws at the back of the autoloader that connect the
support brackets (two screws per bracket) to the autoloader brackets.
4
While supporting the front of the autoloader, remove the four front
screws.
Note:
Do not ship these items if you are returning the autoloader
to the factory.
Caution:
Injury may occur if the unit is not supported when
you remove the front screws. The screws are holding
up the front of the unit.