![Quantum SuperLoader 3A Series Скачать руководство пользователя страница 82](http://html.mh-extra.com/html/quantum/superloader-3a-series/superloader-3a-series_user-manual_770658082.webp)
Chapter 5 Troubleshooting
Autoloader Troubleshooting
Quantum SuperLoader 3A Series User’s Guide
68
A8
Destination Element Full
• Verify the expected destination really does not have a
cartridge.
• Run the
Loader—Health Check
test.
• If destination is a magazine, install and remove a
cartridge from the selected slot and try again. If error
continues, replace the magazine.
• If destination is the tape drive, verify the tape drive
does not have a cartridge.
• Power cycle the autoloader.
• If error continues, contact customer support.
• If the cartridge is in the mailslot opening, remove it.
• Verify that the mailslot is fully closed.
• Verify that there is no debris in the mailslot opening.
A9
Picker Full
• Look in the front of the autoloader and confirm that
the picker is full.
• Run the
Loader—Health Check
test.
• If all previous steps fail, contact customer support.
AA
Picker Cartridge Sensor Error
• Look in the front of the autoloader and confirm the
picker is full.
• Run the
Loader—Health Check
test.
• If all previous steps fail, contact customer support.
AB
Drive Path Sensor Error
• Run the
Loader—Health Check
test.
• Power cycle the autoloader.
• If all previous steps fail, contact customer support.
AC
Mail Slot Door Sensor Error
• Insert a cartridge into the autoloader via the mailslot.
• Power cycle the autoloader.
• If all previous steps fail, contact customer support.
Error
Description
Suggested Actions