Chapter 3 On-board Remote Management
Configurations Page
Quantum SuperLoader 3A Series User’s Guide
37
To set
Auto Clean
:
1
From any page, click the
Configuration
heading. The
Configuration
screen displays.
2
Scroll to
Cleaning Tape
.
If a check mark appears in the box next to
Auto Clean
, the option is
enabled. To disable
Auto Clean
, click the box to remove the check
mark. If no check mark appears in the box next to
Auto Clean
, the
option is disabled. To enable
Auto Clean
, click the box to enter a check
mark.
3
In the
Cleaning Tape Location
field, select the appropriate slot location
where you installed the cleaning tape. If
Auto Clean
is disabled,
cleaning is managed by the backup package you have installed
instead.
4
Click
submit
.
Magazines
3
This setting is used to report the number of storage elements and the
element address to the host. This setting must match the physical
configuration in order for correct information to be reported. This setting
only affects the information reported to the host. This setting does not
affect the access to magazine slots from the front panel or On-board
Remote Management. Those interfaces are based on the physical
configuration.
When configured for
Both
magazines, the autoloader always reports 16
storage elements to the host. This allows the removal and reinstallation of
magazines without affecting what is reported to the host. When
configured for
Left
or
Right
, the autoloader will always report eight
storage elements to the host.
The element addresses vary depending on which magazine is configured.
If
Left
or
Right
is selected, and both magazines are physically installed,
the front panel and On-board Remote Management allow the user access
to the other magazine, but the host will not have access.
To set the
Magazines
option:
1
From any page, click the
Configuration
heading. The
Configuration
screen displays.
2
Scroll to
Magazines
. The
Magazines
options display.