Chapter 3 Operation
Handling Operational Fault Conditions
GoVault™ for Windows User’s Guide
50
Abnormal Hardware
Conditions
3
The GoVault system application software samples three operational
aspects of the internal GoVault dock and cartridge disk drive once a
minute:
• Voltage
• Temperature
• Fan
When it detects that the internal dock temperature, voltage, or fan
operation is abnormal, the GoVault system application software:
• Displays a temperature, voltage, or fan warning message.
• Posts a message in the Windows Application Event log. (Open the
Windows Event Viewer to see this message.)
If the hardware condition remains abnormal for two minutes, the
GoVault system application software:
• Flashes the activity LED indicator on the internal GoVault dock
quickly at approximately four time per second.
• Ejects the cartridge
• Displays a cartridge eject message
If you reinsert a cartridge while the abnormal temperature condition
persists, the GoVault system application software will eject the cartridge
after one minute.
If the hardware condition persists, the GoVault system application
software continues posting messages to the Windows Application Event
log at five-minute intervals.
When the hardware condition returns to normal and remains there for
five minutes, the GoVault system application software:
• Posts a message to the Windows Application Event log indicating
that the hardware operation has returned to normal
• Displays a message that the abnormal hardware condition has
cleared
Table 2
lists the steps you should take to resolve abnormal hardware
conditions.