5 – Non-Interactive Mode Commands
Non-interactive Commands
5-18
SN0054621-00 E
S
-lb
(Perform Loopback Test)
To run a loopback test, enter the
-lb
command as follows:
-lb <
hba_port_inst
> [-STOP] [-EXTLB] [-CNT <
Test Count
>]
Where:
For information on the interactive version of this command, see
“Perform
Loopback Test (CLI Option -lb)” on page 4-31
.
-lc
(Configure Link Configuration)
To configure the link settings, enter the
-lc
command as follows:
-lc <
hba_port_inst
>
The optional parameters are auto-negotiate
[-AUTONEG]
, link speed
[-LNKSPD]
, and flow control
[-FLOW]
. With auto-negotiate on, no entries should
be provided for link speed. For a copper connection and auto-negotiate off, a link
speed of 100 or 10 must be provided. For a fiber connection, the link speed is
always 1000 Mbs. The optional parameter
[-FLOW]
will turn on or off flow control.
-lcd
(Display Configured Link Configuration)
To display the configured link settings, enter the -lcd command. Note that because
a system reset is required for changes in link configuration to take effect, the
settings shown here may be different than the operating link configuration.
CAUTION!
Before doing a loopback test, ensure that the HBA does not have any
outstanding I/O operations.
hba_port_inst
= The HBA port where you do the loopback test.
–STOP
= The loopback test stops if a failure occurs.
–EXTLB
= Runs an external loopback test. By default, runs an internal
loopback test.
-CNT
= Used with
Test Count
to say how many loopback tests to run.
Default is 1.
Test Count
= The number of loopback tests to run. One is the default. To
run more than one test, enter a number between 2–(2^31).
Содержание SANsurfer iSCSI HBA CLI
Страница 32: ...2 Installation and Removal Removing SANsurfer iSCSI HBA CLI 2 14 SN0054621 00 E S Notes...
Страница 136: ...C Target Parameters C 6 SN0054621 00 E S Notes...
Страница 150: ...D Error Codes Non interactive Mode Error Codes D 14 SN0054621 00 E S Notes...
Страница 152: ...E Downloadable File Names E 2 SN0054621 00 E S Notes...