3 – Event Messages
Alarm Events
59060-04 A
3-39
A
(A1007.0039) (Ignoring RADIUS Server server, no shared secret configured)
Meaning:
An attempt was made to authenticate a switch login through a
RADIUS server, but no shared secret exists.
Action:
Configure a shared secret.
(A1007.003A) (Using local user authentication. No radius servers configured for user
authentication)
Meaning:
RADIUS configuration was set to authenticate user accounts
through a RADIUS server, but no RADIUS server was configured.
User accounts will be authenticated by the switch.
Action:
Correct the user authentication order or configure a RADIUS
server.
(A2000.0001) (Pwr1 removed - ALARM SET)
Meaning:
Power supply #1 has failed or was removed from the switch.
Action:
Contact your authorized maintenance provider.
(A2000.0002) (Pwr2 failure - ALARM SET)
Meaning:
Power supply #2 has failed or was removed from the switch.
Action:
Contact your authorized maintenance provider.
(A2000.0004) (power_supply_number AC power may be unplugged or switched off -
ALARM SET)
Meaning:
One of the two power supplies is not receiving power.
Action:
Check the switch power supply and the AC power source.
(A2001.0001) (Pwr2 was installed - ALARM CLEARED)
Meaning:
Power supply #2 was installed.
Action:
None.
(A2001.0002) (Pwr1 OK - ALARM CLEARED)
Meaning:
Power supply OK.
Action:
None.
(A2001.0004) (power_supply_number AC power is good - ALARM CLEARED)
Meaning:
AC power has been restored.
Action:
None.
(A2002.0001) (fan_number was removed)
Meaning:
A field replaceable fan was removed from the switch.
Action: