3 – Event Messages
Alarm Events
59060-04 A
3-31
A
(A1006.0005) (Zoning enforcement error in Nameserver)
Meaning:
An error occurred while checking ACL zoning.
Action:
Contact your authorized maintenance provider.
(A1006.0006) (Zoning conflict, device_WWN and device_WWN do not share an ACL hard
zone, but device_WWN share a soft zone)
Meaning:
The named zone members cannot communicate because they are
members of different ACL hard zones.
Action:
Place both zone members in the same ACL hard zone or exclude
both from ACL hard zones.
(A1007.0001) (Security: Unspecified zoning enforcement error)
Meaning:
A device was not authorized or it failed security checks and will not
be allowed to join the fabric.
Action:
None.
(A1007.0002) (Security: Remote Switch with WorldWide Name (WWN) wwn configured for
chap, no chap configured for local switch. 2-way Authentication Failure)
Meaning:
The device WWN is either not configured in the security data base,
or it is not configured for Challenge Handshake Authentication
Protocol (CHAP).
Action:
Add the device WWN to the active security set if it missing, or
modify the group to allow for CHAP authentication with the other
devices.
(A1007.0005) (Security: Authentication request was rejected by port.)
Meaning:
Indicates that a remote switch rejected a security authentication
attempt. The port will isolate.
Action:
Checks the security configuration on the remote switch to
determine the problem.
(A1007.0006) (Security: Could not validate Authentication Response from port_number,
payload seems to be incorrect.)
Meaning:
The format of the payload of the response frame does not match
what was expected.
Action:
Check for errors on the remote side of the link. Check the
transceiver and cable. Update firmware on remote switch.