background image

3 – Event Messages

Alarm Events

3-6

59060-04 A

S

(A1003.0016) (Releasing Lock held too long by domain_ID)

Meaning:

Zone merge could not complete in the acceptable time.

Action:

Check the status of the switch given by 

domain_ID

.

(A1003.0017) (Activation of zoneset by management server failed due to port port_number 

out of range.)

Meaning:

A zone member defined by domain ID and port was received within 
a management server AZSD command with a port number out of 
range. 

Action:

Check management server application zoning configuration to 
assure zone members are properly configured.

(A1003.001B) (Failing remote zoning configuration, total zoneset limit would be exceeded)

Meaning:

The maximum number of zone sets has been exceeded on the 
switch as a result of a zone merge.

Action:

Reduce the number of zone sets on the remote switch.

(A1003.001C) (Failing remote zoning configuration, total member limit would be exceeded)

Meaning:

The maximum number of zone members has been exceeded on 
the switch due to a zone merge.

Action:

Reduce the number of zone members on the remote switch.

(A1003.001D) (Failing remote zoning configuration, total zones in zonesets limit would be 

exceeded)

Meaning:

The maximum number of zones in zone sets has been exceeded 
on the switch as a result of a zone merge.

Action:

Reduce the number zones on the remote switch.

(A1003.001F) (Failing remote zoning configuration, member limit for zone zone_name 

exceeded, (size= number_of_zones, limit= maximum_number_of_zones))

Meaning:

The maximum number of members for the given zone has been 
exceeded as a result of a zone merge.

Action:

Reduce the number of members in the given zone on the remote 
switch.

(A1003.0020) (Failing remote zoning configuration, total zone limit would be exceeded)

Meaning:

The maximum number of zones has been exceeded on the switch 
as a result of a zone merge.

Action:

Reduce the number of zones on the remote switch.

Содержание QLogic Fibre Channel Switch

Страница 1: ...S i m p l i f y R 59060 04 A Page i QLogic Fibre Channel Switch Event Message Guide Firmware Version 6 8...

Страница 2: ...the right to change product specifications at any time without notice Applications described in this document for any of these products are for illustrative purposes only QLogic Corporation makes no r...

Страница 3: ...Event Logging 2 1 Understanding Severity Levels 2 1 2 2 Displaying Events using the Event Browser 2 1 2 3 Displaying the Events Using the Command Line Interface 2 2 2 4 Configuring the Event Log 2 3 2...

Страница 4: ...Page iv 59060 04 A QLogic Fibre Channel Switch Event Message Guide S Notes...

Страница 5: ...configure the event log how to display the event log and how to download the event log from the switch Section 3 describes the message format and lists the messages 1 1 Intended Audience This manual i...

Страница 6: ...warranty is available during local standard working hours excluding QLogic Observed Holidays 1 3 2 Training QLogic offers certification training for the technical professional for both the SANblade H...

Страница 7: ...Phone 1 952 932 4040 Fax 1 952 974 4910 Europe Middle East and Africa Region Email emeasupport qlogic com Phone Numbers by Language 353 1 6924960 English 353 1 6924961 Fran ais 353 1 6924962 Deutsch 3...

Страница 8: ...1 Introduction Technical Support 1 4 59060 04 A S Notes...

Страница 9: ...re generally not disruptive to the administration or operation of the fabric but are more important than the informative level events Informative The informative level describes routine events associa...

Страница 10: ...uide for your switch for more information about the Show Log command In the command line interface each message has the following format ordinal time_stamp severity source message_ID message_text ordi...

Страница 11: ...tion about the Set Log command 2 5 Archiving and Downloading the Event Log You can use the command line interface to create a file on the switch that contains the most recent 200 entries plus the prev...

Страница 12: ...vice logouts Loss of signal errors To configure port threshold alarms using Enterprise Fabric Suite 2007 open the Switch menu in the faceplate display and select Port Threshold Alarm Configuration The...

Страница 13: ...n contact your authorized maintenance provider 3 1 Fault Events The following fault messages apply only to SANbox 9000 series switches Fault events like alarms require administrator attention and may...

Страница 14: ...FAIL Meaning Application is unable to register with Fault Tolerant FT manager FW_FT_APP_SYNC_FAIL Meaning Failure to synchronize data to the secondary CPU blade FW_FT_CPU_FAILOVER_FAILED Meaning Unabl...

Страница 15: ...al HW_UNSUPPORTED_BLADE Meaning Installed blade is unknown or not supported SENSOR_FAULT Meaning Power Supply blade reports an internal fault temp_sensor_TEMP Meaning The temperature sensor reading is...

Страница 16: ...ure during the hotreset process the switch is being reset normally Action None A1003 000B Failing release of fabric lock held by switch with domain domain_ID Meaning The local switch is locked as the...

Страница 17: ...in the local zoning database with the same name but different membership Action Contact your authorized maintenance provider A1003 0013 Segmenting zone zone_name merge conflict Meaning In non interop...

Страница 18: ...remote zoning configuration total member limit would be exceeded Meaning The maximum number of zone members has been exceeded on the switch due to a zone merge Action Reduce the number of zone members...

Страница 19: ...later A1003 0024 Request already in progress internal lock held Meaning A fabric operation is currently in progress Action Wait and try again A1003 0025 Error reading security set Meaning There was a...

Страница 20: ...e the zone set on the remote switch A1003 002D Zone Merge response indicates failure to merge Isolating link Meaning The attempt to merge two fabrics failed because each active zone set contained a zo...

Страница 21: ...eeds the zoning database limit Action Remove zone sets from the local switch zoning database to allow fabric merge to complete A1003 0035 Merge failed invalid zone data received ISOLATING Meaning A re...

Страница 22: ...he two zones so that they are the same A1003 003B Incomplete merge request sequence received unable to process request Meaning A remote switch sent a merge request that was not understood Action Check...

Страница 23: ...has the same name as the active zone set Action Deactivate the active zone set before deleting the zone set from the zoning database that has the same name as the active zone set A1003 004C Active Zo...

Страница 24: ...lue of the domain ID A1003 0052 ISL group does not contain entry for switch domain_ID Meaning The ISL group does not contain an entry for each switch in the fabric Fabric binding requires an entry for...

Страница 25: ...h Action Examine the zoning configuration for conflicts A1003 0062 Failing delete orphans zoning request fabric locked by switch with domain ID domain_ID Retry command later Meaning An attempt was mad...

Страница 26: ...ello from the remote switch for 80 seconds Routes learned through this link are discarded Action None A1004 0008 Eport Isolating due to ELP Incompatibility Meaning An E_Port isolated due to an ELP Exc...

Страница 27: ...port Isolating due to Merge Zone Failure Meaning An ISL failed because the two active zone sets each have a zone with the same name but different members Action Modify one or both of the zones so that...

Страница 28: ...figure to connect to remote switch Meaning An E_Port isolated because the R_A_TOV timeout values on the two switches do not match Action Modify R_A_TOV so that it is the same on both switches The reco...

Страница 29: ...remote switch to connect through a port that could not configure itself as an E_Port Action Change the port type on the remote switch to G_Port or GL_Port A1004 002D Non interop Legacy switch setting...

Страница 30: ...interoperability mode settings firmware versions and licensing on the remote switch Otherwise contact your authorized maintenance provider A1004 0035 Failed to connect to a switch due to incompatibili...

Страница 31: ...World Wide Name WWN device_WWN assigned domain domain_ID fabric binding indicates it should use domain_ID Meaning User activated fabric binding conflicts with the current domain ID assignment Action...

Страница 32: ...nding list A1004 0053 Adding Denial of Service entry for source FC Address 0xaddress Meaning A number of frames from the indicated address have been received These frames are from a source that is not...

Страница 33: ...error insufficient credit in pool Extended credit not granted for port port_number Meaning Insufficient credits were available in the credit pool to grant the credit request Action Decrease the number...

Страница 34: ...Fabric Login FLOGI from address FC_address failed Meaning The payload of the FLOGI was not valid Action Check device connection or replace the device If the problem persists contact your authorized m...

Страница 35: ...e port Action Replace the SFP A1005 0041 Setting port admin state DOWN due to POST failure Meaning The port failed the power on self test and has been disabled Action Contact your authorized maintenan...

Страница 36: ...has been cleared Action None A1005 004D ICCnumber cable not installed ALARM SET Meaning A HyperStack cable is not connected to the specified Inter Chassis Connection ICC port and the associated alarm...

Страница 37: ...n progress The Ethernet ping was canceled Action Retry the Ping command A1005 0053 Canceling FC ping as a result of a CPU switchover Meaning A CPU blade switchover occurred while an Fibre Channel ping...

Страница 38: ...CPU blade switchover occurred while a CIM Edit session was in progress The edit session was canceled Action Reopen the CIM Edit session A1005 005B Canceling system edit mode as a result of a CPU swit...

Страница 39: ...and is functioning normally Action None A1005 0063 CPU never entered HotStandby state Meaning Secondary CPU never entered HotStandby state and therefore the switch is not fault tolerant Action Contact...

Страница 40: ...ating problem has been corrected Action None A1005 006A User account account_name has expired Meaning The named user account has exceeded its expiration date Action Review the user account and make th...

Страница 41: ...P address of address on interface interface Meaning The switch was unable to obtain its IP address from the Dynamic Host Configuration Protocol DHCP server The static IP address will be used Action In...

Страница 42: ...der A1005 007A Blade fault fault reported from primary CPU powering off blades ports Meaning A blade fault has occurred on the SANbox 9000 primary CPU blade I O blades are being powered down Action Co...

Страница 43: ...configured for chap no chap configured for local switch 2 way Authentication Failure Meaning The device WWN is either not configured in the security data base or it is not configured for Challenge Han...

Страница 44: ...EFMD frame The port will be isolated Action Check remote switch for the reason that the EFMD frame was rejected It is possible that the FabricBindingEnabled parameter is different on the two switches...

Страница 45: ...ssible error condition Reset the port to retry again If errors continue disable CHAP for this device if it belongs in the fabric A1007 0010 Security Chap session Receive Challenge indicates bad state...

Страница 46: ...ard format for the frame payload Within the header portion of the payload there are some flags that are supposed to be set to zero This frame has the flags set to something other than zero Action Chec...

Страница 47: ...erver A1007 0024 Invalid access accept from RADIUS server IP_address port bad or missing Service Type Meaning A service type RADIUS attribute was not found within a RADIUS packet Action This is a RADI...

Страница 48: ...ble or disable fabric binding on all switches A1007 002B Security Chap session Negotiate Authentication failed Meaning Local switch received an authentication negotiate frame which failed processing E...

Страница 49: ...A RADIUS server was configured with invalid data for the shared secret This is a required configuration field for the RADIUS server to be used Action Set the shared secret in the switch RADIUS server...

Страница 50: ...n Add the device to the switch binding list A1007 0035 Port taken offline due to switch binding failure following configuration change Meaning A configuration change was made to the switch binding lis...

Страница 51: ...wer supply 1 has failed or was removed from the switch Action Contact your authorized maintenance provider A2000 0002 Pwr2 failure ALARM SET Meaning Power supply 2 has failed or was removed from the s...

Страница 52: ...nal and the alarm is cleared Action None A2003 0003 Fan flow match ALARM CLEARED Meaning The opposing fan air flow condition has been corrected Action None A2004 0001 Secondary cpu_blade assuming cont...

Страница 53: ...up This switch is not currently operational Action Enter the Show Post Log command to investigate A3003 0002 POST detected a fatal error the last time it ran and will be re executed Meaning A fatal ha...

Страница 54: ...8 0000 The configuration area was damaged or a Remake Filesystem was performed from PROM mode You must perform a config restore to clear this error Meaning The configuration area was damaged or a Rema...

Страница 55: ...been returned to its state before the Hotreset command was entered Action If acceptable enter the Reset Switch command to reboot the switch Contact technical support if a non disruptive code load and...

Страница 56: ...mand because fabric zoning lock is already held by another switch in the fabric C 8300 000C Zoning Couldn t acquire lock from domain domain_ID Meaning Fabric may be changing couldn t acquire lock Wait...

Страница 57: ...onds Meaning The switch is being reset as a result of a command from a user interface C 8400 0009 Switch The switch will hardreset in several seconds Meaning A hard reset of the switch is pending C 84...

Страница 58: ...ing A security merge has occurred and the security edit session has been cancelled C 8400 001C Switch The switch is being reset this may take several seconds Meaning The switch is being reset C 8400 0...

Страница 59: ...ly Meaning Changes have been made to the network configuration which may interrupt your connection to the switch C 8400 0042 Switch Warning deleting the active zoneset may cause fabric isolation Meani...

Страница 60: ...ate synchronization lost Meaning The Network Time Protocol NTP Server synchronization was lost C 8400 0050 Switch Upgrading License allowing manufacturing setup mode capability Meaning The license upg...

Страница 61: ...F Switch Upgrading License for SMI S capability Meaning The Common Information Model CIM license was applied successfully C 8400 0060 Switch Warning Illegal transparent mode configuration primary and...

Страница 62: ...fully C 8400 0079 Canceling config edit mode as a result of a CPU switchover Meaning A CPU blade switchover occurred while a Config Edit session was open C 8400 007A Resaving the zoning config as a re...

Страница 63: ...ce for port port_number Meaning Switch could not read and verify the media module ID This could be caused by a media discovery error a bad checksum in the media serial ID an improperly installed media...

Страница 64: ...ink ISL a time out value has been reconfigured Meaning The Resource Allocation R_A_TOV or Error Detect E_D_TOV timeout value has been reconfigured E_Ports will be automatically reset to inform the nei...

Страница 65: ...Unable to test profile profile because the FromEmailAddress has not been configured in the CallHome setup Meaning The test of the named profile failed because the FromEmailAddress was not specified in...

Страница 66: ...ns Meaning Communications have been re established with one of the Simple Mail Transfer Protocol SMTP servers following a communications failure C 8B00 0016 SMTP server ip_address port port_number did...

Страница 67: ...sponse received from switch with domain ID domain_ID Meaning The switch is attempting to do a fabric unlock through a Release Change Authorization request but a remote switch indicated a failure This...

Страница 68: ...A port was disabled by the threshold monitoring application before the hot reset and is still disabled after the hot reset W 8400 0035 Switch Retrying port port_number that was Downed due to excessive...

Страница 69: ...switch attempts to resend the email message using the specified server port and delay W 8B00 0010 Will retry sending via SMTP server ip_address port port_number Meaning After receiving a transient err...

Страница 70: ...o resend an email message to the recipient in the named profile through the specified Simple Mail Transfer Protocol SMTP server has failed The Call Home service will not attempt to resend the message...

Страница 71: ...e the Switch Symbolic Name was not changed to match the registered name I 8200 0101 mserver Cannot map non printable characters to Switch Symbolic Name Meaning The RIELN management server command was...

Страница 72: ...face FDMI server on this switch has been configured disabled so any FDMI requests received by the switch will be rejected I 8300 0004 zoning New Active ZoneSet zone_set_name Meaning A new zone set has...

Страница 73: ...I 8400 0024 Switch Successful login user account_name without admin privilege Meaning A user without admin authority has successfully logged into the switch The IP address of the user is unknown I 84...

Страница 74: ...MFSEnable to False I 8400 003A Switch MFSEnable automatically set to False since LCFEnable has been set to True Meaning Setting the Set Config Port parameter LCFEnable to True automatically sets the...

Страница 75: ...solated for reason reason Meaning The E_Port that previously isolated for the stated reason is now reinitializing I 8700 0008 EPort Link State Record LSR aged out for domain ID domain_ID Meaning A rec...

Страница 76: ...e link manually I 8F00 000B Login Changed Meaning The login to the fabric has changed The description field will show the reason for the change in the login I 8F00 000C Fabric Status status Meaning Th...

Отзывы: