42
Contacting Cond (S11-43)
1000 µS/cm
LoLo Alarm
Low Alarm
High Alarm
HiHi Alarm
Additional Settings for Contacting Coductivity:
Temp Comp Factor
Cell Constant
Cable Length
Gauge
Units
Name
Type
Electrodeless Cond (S11-43)
1000 µS/cm
LoLo Alarm
Low Alarm
High Alarm
HiHi Alarm
Additional Settings for Electrodeless Conductivity:
Deadband
Reset Calibration Values
Cal Required Alarm
Alarm & Datalog Suppression
Smoothing Factor
Default Temp
Installation Factor
Range
Temp Compensation
Temp Comp Factor
Cell Constant
Cable Length
Gauge
Units
Name
Type
Temperature (S11-43)
20 ºC
LoLo Alarm
Low Alarm
High Alarm
HiHi Alarm
Additional Settings
:
Deadband
Reset Calibration Values
Cal Required Alarm
Alarm & Datalog Suppression
Smoothing Factor
Name
Element
pH (S11-43)
7.00
LoLo Alarm
Low Alarm
High Alarm
HiHi Alarm
Additional Settings for pH Sensor:
Deadband
Reset Calibration Values
Cal Required Alarm
Alarm & Datalog Suppression
Smoothing Factor
Buffers (pH only)
Default Temp
Cable Length
Gauge
Electrode
Name
Type
Contacting Conductivity (S11)
1000 µS/cm
Alarms
Status
Raw Value
Temperature
etc. Details Screen Content varies with sensor type
Ccond (S11)
Temp (S12)
1000
µS/cm
50.5
°F
Cond (S13)
Temp (S14)
1000
µS/cm
50.5
°F
pH (S21)
Temp (S22)
8.95
80.1
°F
Unassigned (S23)
Unassigned (S24)
List of Possible Inputs
Contacting Conductivity
Electrodeless Conductivity
Temperature
pH
ORP
Disinfection
Generic
Transmitter/AI Monitor
Tank Level
Fluorometer
Flowmeter, Analog Type
DI State
Flow Meter, Contactor type
Flow Meter, Paddlewheel type
Feed Monitor
Counter
Remote Modbus DI State
DI Counter
Calculation Virtual Input
Redundant Sensor Virtual Input
Raw Value Virtual Input
Disturbance Virtual Input
Remote Modbus Virtual Input
Corrosion Rate
Corrosion Imbalance
Home Inputs Outputs Graphs HOA
Config
Contacting Conductivity (S11)
1000 µS/cm
One-Point Process Calibration
One-Point Buffer Calibration
Open Air Calibration (Conductivity inputs only)
Zero Calibration (Disinfection inputs only)
INPUTS
24-Hour Minimum Maximum and Averages
Calibration Gain and Offset
Last Calibration
Type
Sensor Board
Two-Point Buffer Calibration
(pH/ORP inputs only)
Three-Point Buffer Calibration
(pH/ORP inputs only)
One-Point Analog Calibration
(4-20 mA inputs only)
Two-Point Analog Calibration
(4-20 mA inputs only)
Tank Level (S11-S46)
55 gal
LoLo Alarm
Low Alarm
High Alarm
HiHi Alarm
Additional Settings for Tank Level:
Deadband
Reset Calibration Values
Alarm & Datalog Suppression
Units
Tank Capacity
Empty At
Full At
Smoothing Factor
Transmitter
Name
Type
Fluorometer (S11-S46)
20 ppm
LoLo Alarm
Low Alarm
High Alarm
HiHi Alarm
Additional Settings for Fluorometer:
Deadband
Reset Calibration Values
Cal Required Alarm
Alarm & Datalog Suppression
Smoothing Factor
Transmitter
Max Sensor Range
Dye / Product Ratio
Name
Type
ORP (S11-43)
500 mV
LoLo Alarm
Low Alarm
High Alarm
HiHi Alarm
Additional Settings for ORP Sensor:
Deadband
Reset Calibration Values
Cal Required Alarm
Alarm & Datalog Suppression
Smoothing Factor
Cable Length
Gauge
Name
Type
Additional Input Details:
Additional Calibration Options:
Generic (S11-S43)
20.0 ppm
LoLo Alarm
Low Alarm
High Alarm
HiHi Alarm
Additional Settings for Generic Sensor:
Deadband
Reset Calibration Values
Cal Required Alarm
Alarm & Datalog Suppression
Smoothing Factor
Sensor Slope
Sensor Offset
Low / High Range
Cable Length
Gauge
Units
Electrode (Linear or Ion
Selective)
Name
Type
Transmitter / AI Monitor (S11-S46)
100%
LoLo Alarm
Low Alarm
High Alarm
HiHi Alarm
Additional Settings for Transmitter and AI Monitor:
Deadband
Reset Calibration Values
Cal Required Alarm
Alarm & Datalog Suppression
Smoothing Factor
Transmitter
4 mA Value
20 mA Value
Units
Name
Type
Disinfection (S11-43)
2.0 ppm
LoLo Alarm
Low Alarm
High Alarm
HiHi Alarm
Additional Settings for Disinfection Sensor:
Deadband
Reset Calibration Values
Cal Required Alarm
Alarm & Datalog Sup-
pression
Smoothing Factor
Cable Length
Gauge
Name
Sensor
Type