RLX2-IHx Series ♦ 802.11a, b, g, n
RLX2-IHx Series Quick Setup
Industrial Hotspots
User Manual
ProSoft Technology, Inc.
Page 32 of 248
3.2.3 RLX2-IHNF-WC Radio Connections
This radio is suitable for Class I, DIV2 hazardous locations. The power and Ethernet
connections for these radios are a set of wires that protrude through a single conduit hub
located on the bottom of the case.
One wire is terminated with an RJ45 connector for Ethernet connections. This wire
can also supply power when attached to a PoE Injector.
The second wire supplies power to the radio if not attached to a PoE Injector. If you
are using PoE, make sure you insulate this wire from the other wires to prevent
shorting.
To install this radio
1
Place a seal cap over the top of the conduit as shown below.
2
Run both wires down through the conduit.
3
Push the conduit up into the permanently installed connector on the bottom of the
radio. Push it up as far as it will go.
Warning: The recommend conduit is Thomas & Betts
®
PMA Series, Cat. No. CYLT-23B.