155
Chapter 8: Troubleshooting
•
VTrak is Beeping (below)
•
CLU Reports a Problem (below)
•
WebPAM PRO Reports a Problem (page 156)
•
LEDs Display Amber or Red (page 157)
•
Event Notification (page 160)
•
Critical & Offline Logical Drives (page 164)
•
Connection Problems (page 166)
This Chapter covers troubleshooting procedures for VTrak.
VTrak is Beeping
VTrak’s audible alarm has four sound patterns:
•
Beep. Beep. Beep. – Indicates that a logical drive is rebuilding
•
Beep-beep, beep-beep, beep-beep. – Indicates that a logical drive is critical
•
Beep-beep-beep, beep-beep-beep. – Indicates a problem with a field
replaceable unit (FRU)
•
10 second continuous beep – Indicates that a logical drive is offline
See
Critical & Offline Logical Drives
on page 164.
For FRUs, see
Back of Enclosure
on page 158.
CLU Reports a Problem
The CLU can report a variety of problems with the VTrak. In order to see them,
the CLU must be open. Some conditions are only indicated when you select the
corresponding function.
In this example, let us check logical drive status.
1.
Open the CLU.
2.
Select Logical Drive management > View Logical Drive information
3.
Observe the status of your logical drives.
********************** Logical Drive information ********************
Id Name
Mode
Stripe
Block Size
Status
-------------------------------------------------------------------------------------
1
FirstLD
RAID5
64K
107 GB Critical
In the example above, logical drive “FirstLD” is critical. See
Critical & Offline
Logical Drives
on page 164.