Chapter 5: Management with the CLU
121
Enable/Disable SMART of Logical Drive's member disks
Use this function to enable or disable the SMART setting on all the disk drives
belonging to a logical drive.
*****************Modify SMART check*****************
Id
Logical Drive Name
SMART Check
---------------------------------------------------------------
3
c
enabled
Select the Logical Drive to modify SMART check option
Press R to return after finished>3
Want to modify SMART check option for Logical Drive 3(y/n)?>y
Please wait...
*****************Modify SMART check*****************
Id
Logical Drive Name
SMART Check
----------------------------------------------------------------
3
c
disabled
Select the Logical Drive to modify SMART check option
Press R to return after finished>
Logical Drive name
Use this function to change the name of a logical drive.
**************Modify Logical Drive name*************
Id Name
Mode
Size
---------------------------------------------------------------
3
c
RAID10
71 GB
Select the Logical Drive to modify its name
Press R to return after finished>3
Want to modify the name for Logical Drive 3(y/n)?>y
Please enter the new Logical Drive name>logdrv
**************Modify Logical Drive name*************
Id
Name
Mode
Size
----------------------------------------------------------------
3
logdrv
RAID10
71 GB
Select the Logical Drive to modify its name
Press R to return after finished>
Содержание VTRAK 15100
Страница 1: ...VTRAK 15100 USER MANUAL Version 1 4 PROMISE VTrak 15100 ...
Страница 42: ...VTrak 15100 User Manual 34 ...
Страница 60: ...VTrak 15100 User Manual 52 ...
Страница 176: ...VTrak 15100 User Manual 168 ...
Страница 186: ...VTrak 15100 User Manual 178 ...