The module's data mapping feature can be utilized to move this data into the
module's database area. This way the data can be made available to all drivers
on the module for use on any of the connected networks. If it is not mapped into
the module's database, the data will only be available through the
Configuration/Debug Port.
The Time is valid status register will be set to 1 if the SNTP time is valid. If the
time is not valid, the register will be set to 0. All the other registers are counters
used to determine the functionality of the driver.
This version of the driver supports SNTP Revision 3 and stratum between 1 and
14.
5.6
Radio DF1 Pass-Through Server
This section can be configured in two ways:
Connecting through a wireless laptop or PC
OR
Connecting thru laptop or PC connected to an Ethernet network using
Wireless Access Point
5.6.1 Connecting through Wireless Laptop or PC
1
Locate the Wireless Network.