8.5 Motor settings
Various settings for the drive motor can be changed via „Settings“ -> „Motor
settings“ in the menu
.
8.5.1 Manual speed
Manual drive speed sets the speed at which the tool holder (18) moves when using
the „manual back“
or “manual forward”
buttons.
8.5.2 Speed mode
There are two speed modes:
Normal 0
– 300 mm/s:
The normal speed mode is appropriate for most uses.
Schnell 0
– 600 mm/s:
The fast mode is for procedures requiring high
drawing speed.
If not specifically required otherwise, i
t is recommended to use the „Normal“ speed
mode for the procedures.
8.5.3 Acceleration mode
There are three different acceleration modes:
Normal:
The normal mode is appropriate for most uses.
Increased:
The increased acceleration is for uses where the top speed of the
tool holder (18) needs to be reached quickly.
High:
The high acceleration mode is only appropriate for uses with very
high speed, requiring the top speed of the tool holder (18) to be
reached as fast as possible.
High acceleration mode can lead to a jerk at the start of the
process.
If not specifically required otherwise, i
t is recommended to use the „Normal“
acceleration mode for most procedures.