Page 33
8.1.7 Setting the cycle speed
The double stroke speed (cycle speed) can be set by tapping the Speed field. A
slider will appear on the right side of the touch screen to change the value. The
value can also be changed by using the
and
button.
The preset double stroke speed will automatically be saved in the currently selected
layout.
8.1.8 Setting the stroke length
The stroke length can be set by tapping the Length field. A slider will appear on the
right side of the touch screen to change the value. The value can also be changed
by using the
and
buttons.
The preset stroke length will automatically be saved in the currently selected layout.
8.1.9 Position
The Position field shows the current position of the tool holder (18) relative to the
previously defined zero position.
8.1.10 Menu
The menu can be opened using the „Menu“
button. Various settings can be
changed from here.
If the device is equipped with the
appropriate modification set, also other
tests like crocking, scratching or
applications can be carried out with the
Proceq ZAA 2600 universal unit.
To carry out scratching tests the
application mode has to be used.
To get back to the machine mode
„Crock / Scrub“ choose „setup“ in the
menu, then select machine mode
„Crock / Scrub“.