14
4.
Tank sender
The tank sender is mounted in the LPG tank. The tank sender is an electrical device which measures the
fluid level in the tank.
5.
Reducer/regulator
The reducer is mounted in the engine compartment.
The reducer transforms the LPG from a liquid state into a vapour state and will reduce the tank
pressure to system working pressure.
6.
Temperature sensor
The temperature sensor is fitted into the reducer and measures the coolant temperature in the
reducer. The temperature sensor sets the switch over moment of the system.
7.
Filter unit
The filter unit is fitted between the reducer and the injector rail. The filter unit is filtering the pollution
from the dry gas to protect the injectors.
8.
Pressure / temperature sensor
The filter unit is equipped with a pressure/temperature sensor. The sensor measures the pressure and
the temperature of the gas.
9.
Injector rail
The injector rail is fitted close to the inlet manifold. The injector rail consists of injectors which are
metering the supply of vapourized LPG sequential into the engine.
10.
AFC-2.0 computer
The AFC-2.0 (computer) is located in the engine compartment. The AFC-2.0 is the centre of the
installation and processes all incoming signals and drives the different actuators.
11.
Fuel selector switch
The fuel selector switch is located on the dashboard or on the centre console. With the switch you
operate the SilverLine-2.0 system.
12.
Fuses
The fuses are located in an available place in the engine compartment. The fuses protect the electronic
circuit from overloading.