The following table shows all the possible combinations of LED activation,
with reference to the operational state of AURORA.
Key:
LED on
LED flashing
LED off
Any of the above conditions
LED STATUS
OPERATIONAL
STATUS
NOTES
1
green:
yellow:
red:
AURORA self-
disconnection
Input voltage less than 70%
of the set start-up voltage for
both inputs
2
green:
yellow:
red:
AURORA initialization,
loading the settings, and
waiting for grid check
It is in a transition status due
to operating conditions
being checked
3
green:
yellow:
red:
AURORA is powering
the grid
The machine is operating
normally (search for the
maximum power point or
constant voltage)
4
green:
yellow:
red:
Anomaly detected in the
isolation system
Leakage to the ground
detected
5
green:
yellow:
red:
Anomaly – fault!!!
The fault may be internal,
or it may be an external
anomaly,
refer to the alarm which
will appear on the LCD
display
Содержание Aurora PVI-10.0-I-OUTD-400
Страница 46: ...Use and installation manual Page 45 of 97 PVI 10 0 12 0 I OUTD S 400 Rev 1 3 Fig 19 Data Transmission Options ...
Страница 99: ...AURORA Inverter Fotovoltaici MANUALE INSTALLAZIONE E OPERATORE Model number PVI 10 0 12 0 I OUTD S 400 Rev 1 3 ...
Страница 143: ...Manuale d uso e installazione Pagina 45 di 97 PVI 10 0 12 0 I OUTD S 400 Rev 1 3 Fig 19 Data Transmission Options ...
Страница 196: ...AURORA Photovoltaik Wechselrichter INSTALLATIONS UND BEDIENUNGSHANDBUCH Model number PVI 10 0 12 0 I OUTD S 400 Rev 1 3 ...