(PVI-10.0/12.0-I-OUTD(-S)-400 Rev:1.3)
6.2
Accuracy of measured values
Every measurement is subject to errors.
The tables below outline the following information for each
measurement:
units of measurement;
range;
resolution.
Name of
measured
variable
Unit of
measur
ement
Resolution
Nominal
precision
Display
Value
Input voltage
PV No. 1
VP1
Vdc
1 V
160mV
2%
Input voltage
PV No. 2
VP2
Vdc
1 V
160mV
2%
Input current
PV No. 1
IP1
Adc
0.1 A
7mA
2%
Input current
PV No. 2
IP2
Adc
0.1 A
7mA
2%
Power supplied
PV No. 1
Pin1
W
1 W
6W
2%
Power supplied
PV No. 2
Pin2
W
1 W
6W
2%
Output voltage
Vout
V
1 V
200mV
2%
Output current
Iout
A
0.1 A
20mA
2%
Output power
Pout
W
1 W
9W
2%
Frequency
Freq
Hz
0.01
0.01
0.1%