145
~
2.9.2 LPG: adjustment of the burner-jets to minimal-flame
I
NSTRUCTIONS FOR THE QUALIFIED PROFESSIONAL
(
GAS FITTER
)
❖
The
minimal-flame
must be adjusted properly for all burner-jets even when the
appliance is supplied with LPG.
1.
Ignite a gas burner (s. chapter 4.2.5 I
GNITION OF A GAS BURNER
) and set it to the
minimum level « » (
D
) using the rotary knob (
A
). The mark on the rotary knob
(
A 1
)
must
face the minimum level (
D
/ s. fig. below).
To ignite a gas burner, turn the respective rotary knob to the minimum level (
D
)
in
anticlockwise direction only
, otherwise you may damage the rotary knob.
2.
Then pull off the rotary knob (
A
).
Fig. similar: modifications are possible.
A
R
OTARY KNOB
A 1
M
ARK OF THE ROTARY KNOB
B
P
OSITION OF THE GAS BURNER
(cooking zone)
C
G
AS BURNER
« O
FF
» (no gas supply)
D
M
INIMUM LEVEL
(minimal-flame / minimum gas supply)
E
M
AXIMUM LEVEL
(maximum gas supply)
3.
Then adjust the minimal-flame of the burner-jet properly. To adjust the minimal-
flame of a burner-jet with LPG supply, the relevant screw of the gas burner
must
be
completely
tightened
in clockwise direction
(one whole turn / 360°) using
a flat-head screwdriver (s. fig. below).