133
~
A
H
OSE CONNECTION
B
G
AS CONNECTION OF THE APPLIANCE
C
S
EAL
D
R
UBBER GAS HOSE
E
C
LAMP
(according to standard)
WARNING!
Never forget to insert the seal!
WARNING!
The tightening torque between connections
containing a
seal
must not
exceed 10 Nm.
WARNING!
After installation, a leak test of the gas hose, gas hob and
the complete installation must be carried out. Ensure, that the main
connection does not exert any tension on the hob. The gas hose must not
contact any movable part and must not pass any place in which it can be
kinked or blocked.
WARNING!
No tension force must be exerted on the connections!