OPERATING AND INSTALLATION INSTRUCTIONS LBE 250 / LBE 500
PAGE 8
Electrical system/electronics
Work on the electrical plant
parts may be performed only
by electricians. If maintenance work or
repairs are performed, the device should
be de-energised. In case of faults in the
electrical voltage supply, shut down the
device immediately. Use only original
fuses with the required current strength.
Check the electrical equipment of the
device regularly. Discovered defects like
loose connections or scorched cables
must be eliminated immediately. After
the electrical work or servicing has been
performed, the safety measures should
be tested (e.g. earthing resistance).
Requirement on the installation site
The installation of the air humidifica-
tion unit may take place only in rooms
that have an existing water outlet. In
addition, safety measures that automa-
tically close the water supply to the air
humidification unit in case of leakage
(e.g. safety valve/water stop) must be
taken within the room. The air humidi-
fication unit is designed in IP20 type of
protection.
4. Transport and storage
To prevent damage during transport due
to force, the air humidification unit must
be handled carefully. During transport
by hand, reasonable human lifting and
carrying forces must be observed.
The unit may not be transported by the
connecting cable. Impacts and shocks
should be avoided.
Age
Reasonable load in kg
Women
Men
15 – 18 years
15
35
19 – 45 years
15
55
Over 45 years
15
45
4.1 DIMENSIONS AND WEIGHT
LBE 250
LBE 500
Dimensions of the packing unit (B x H x T)
800 x 460 x 420
mm
870 x 600 x 600
mm
Weight of the packing unit without optional accessories
28 kg
62 kg
4.2 PACKAGING
The safety labels attached to the box ab-
solutely must be observed. During deli-
very, look out for and check any damage
to the packaging or device. Problems or
damage must be reported immediately.
4.3 STORAGE
The device must be stored in the pa-
ckaging in a dry, dust-free, and frost-
protected manner. Avoid storage periods
that are too long (recommendation: one
year maximum).
4.4 CHECK FOR COMPLETENESS
When the device is delivered, make
sure:
•
The type and serial numbers on the
type plate correspond with the infor-
mation in the order and delivery docu-
ments.
•
The equipment (optional accessories)
is complete.
•
All parts are present in a perfect state.
Note:
In case of any transport damage
and/or missing parts, you must inform
the transport company or suppler imme-
diately in writing.
4.5 SCOPE OF SUPPLY
The delivery comprises the followin:
•
the air humidification unit
•
the operating and mounting instruc-
tions
•
accessories like: the water connection
set
(see Chapter 17.3)
•
optional accessories like: the pumps/
mixer connection set
(see Chapter 17.4)
S
PE
CI
A
LI
S
T PER
S
O
NNEL
G
ENER
A
L
US
ER