OPERATING AND INSTALLATION INSTRUCTIONS LBE 250 / LBE 500
PAGE 44
7.
Switch the decalcification to ON in the
“Decalcification”
menu item of the expert menu previously selected.
8.
The decalcification programme will start. The tank is
emptied again. The rotor starts and the UV lamp is
deactivated. After the discharge pump has been
switched off (noise will get softer after switch-off) and
the tank has been emptied, the cleaning agent can be
filled in. Fill in the cleaning agent using a tube, so that
the cleaning agent (a cleaning agent on an organic
basis) is not spread in an uncontrolled fashion!
When filling the cleaning agent in, take care to
observe the rotating rotor! Make sure that no
fluids are spread onto the electrical components!
Filling quantity of the cleaning agent with an air humidifi-
cation unit 250 = approx. 2.5 litres
Filling quantity of the cleaning agent with an air humidifi-
cation unit 500 = approx. 6 litres
If the quantity of cleaning agent used is too large,
the medium will possibly overflow.
The decalcification programme works automatically and
takes approx. 120 minutes. During this time, several
rinsing processes take place.
9.
When the decalcification programme has been
completed, the air humidification unit automatically
changes to
the controll status
(„CLOSED-LOOP
CONTROL ON” or “AUTO standby“).
UV lamp switches on again!!! Do not look into the
lamp!
10.
Activate the expert menu again
, so that the rotor and
the UV lamp are deactivated.
11. Re-establish the perfect condition of the device
(remove drip water, plastic foil, adhesive tape)
12.
Mount the
rotor cover
(see point 6) and the
device
cover
(see point 4).
Sharp edges of plate (danger of injury).
13.
By pressing the “Back” button, the expert menu is
deactivated and the air humidification unit changes
back to the controll status (see point 2).
UV lamp switches on again!!! Do not look into the
lampt!
14. Now the ventilation unit can be switched on again.
US
ER
G
ENER
A
L
S
PE
CI
A
LI
S
T PER
S
O
NNEL
Descaling
Off
<
Descaling On
Expert
<
Code?
------
Time Valve
Wat.Rep.
Floating switch
Time Valve
Wat.Rep. 260s
Floating switch
On Off
Time Valve Ctrl. -
030s
Time Valve Ctrl.
Runtime Mixer
Time Int. Mixer
Time Rinsing
Reset UVC
UVC Operation
Error Messages
Time Int. Mixer
005min
Time Rinsing
010min
Runtime Mixer
006s
01: No Fault
Rec.
UVC Operation
00
001 h
Reset UVC
Yes No
Fact.Setting
Air Curr.Setup
Descaling
Fact.Setting Yes
load?
No
Hi:680 Lo:260
Dta:080 F1 +-1
Descaling On
Off
Air Heating
Air Heating On
Off
Status storage
AutoStby activ
Ext.Temp.Offset
Status storage 1
S: 15m 10h 003d
AutoStby activ On
4
Off
Ext.Temp.Offset
+0.0
Language
English
German Off
Humidity max. 80 %
Humidity rel.
Humidity max. On
Off
Humidity rel. On
Off