COMMERCIAL-GRADE

GSH75™ HUMIDIFIER

75 PINTS PER DAY

PRODUCT# 700860

Exclusively distributed by:

www.sunlightsupply.com

All design and specifications herein are subject to change without

notice for product improvement. Contact Ideal Air for

details, updates and other information.

Contact Ideal Air Support directly

at [email protected] or call

1-877-9-IDEAL-1

Product not working properly?

DO NOT

 return this product to the

store where you purchased it.

For answers to most common questions and a complete

technical support library please visit www.ideal-air.com

cifications herein are subject to

oduct improvement. Contact Id

ls, updates and other informatio

most common questions an

t library please visit www.i

Содержание GSH75

Страница 1: ...COMMERCIAL GRADE GSH75 HUMIDIFIER 75 PINTS PER DAY PRODUCT 700860 ...

Страница 2: ...COMMERCIAL GRADE GSH75 HUMIDIFIER EXPLODED VIEW DIAGRAM IDEAL AIR PRODUCT 700860 27 20 29 40 33 34 39 38 37 36 26 32 19 25 23 22 21 17 15 18 16 31 24 30 35 ...

Страница 3: ...ot let children play with the appliance If the power cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified person in order to avoid a hazard Unplug the appliance during filling and cleaning Follow the instructions included regarding filling cleaning and descaling Maximum permissible water pressure in pascals 1 2 MPa Minimum permissible water pressure in p...

Страница 4: ...ging unit gravity feed Power Connection Plug the unit directly into an electrical outlet for evaluation Listen for a smooth quiet operation Motor shaft should be centered and vertical Make any necessary adjustments If the power cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Operation WARNING Designed for atomizing...

Страница 5: ...ded Overflowing Pan An overfilled pan can cause poor quality fog and wetness around the unit A leaky float valve or a float that has filled with water may be the problem To check the float raise it out of the water and visually inspect it No water should be inside and it should not sink If OK then check for leaky valve Turn water off and remove the fogger from the pan Empty the pan and towel dry H...

Страница 6: ...calcium build up If build up deposits are present disconnect the water and take the unit outside Pour calcium dissolving solvent available in local hard ware stores in pan and operate unit outside to soften and remove the deposits About once a year remove the housing to check the SST Atom izing Screen to be sure the slots are clear of mineral build up To clean scrub with a calcium dissolving solve...

Страница 7: ..._________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ _______________...

Страница 8: ...l Air Support directly at support ideal air com or call 1 877 9 IDEAL 1 Product not working properly DO NOT return this product to the store where you purchased it For answers to most common questions and a complete technical support library please visit www ideal air com cifications herein are subject to oduct improvement Contact Id ls updates and other informatio most common questions an t libra...