Technology Module TM StepDrive 1x24..48V/5A
MA 1303-A007 EN
44
6.5.4.3 Normally Closed (NC) or Normally Open Contact (NO)
Input S1/2/3 can be used for opening and closing switches. If the input is used, its status
will be indicated by LED S1/2/3. The LED shines, when the input is active, i.e. depending
on the switch type, the LED shines, when a normally closed contact has opened or when a
normally open contact has closed.
Parameterisation of the limit switches
By means of parameterisation you determine whether you wire normally closed (NC) or
normally open (NO) for the limit switches.
NC means: the limit switches are activated by a 0 signal. When the limit switches are
reached, the corresponding control bit is deleted.
N/O contact means: the limit switches are activated by a 1 signal. When the limit switches
are reached, the corresponding control bit is set.
Value adjustable: 0 = NC contact; 1 = NO contact