phytron
43
MA 1303-A007 EN
6.5.4 Inputs
The function of the inputs differs depending on the operating mode:
6.5.4.1 Operating Mode Positioning (PM mode)
The three parameters "Function input S1/2/3" each link one input to its logic function. Each
input can be used as left limit switch, right limit switch, reference switch or remain unused.
Each logic function may only be assigned to one input.
Value adjustable: NO
Limit
Limit switch
–
Reference switch
The "Type of input S1/2/3" parameter determines whether you want to wire normally
closed (NC) or normally open (NO) for the limit switches.
NC: the limit switches are activated by a 0 signal.
NO: the limit switches are activated by a 1 signal
6.5.4.2 Operating Mode Technology Object (TO mode)
In this operating mode, there is only one input, as reference switch. You can select with
this parameter, which input functions as reference switch as normally closed or normally
open contact.
The other two inputs remain unused.