8.3 Stop Conditions
8.3.1 Directed Hold Traversing Job
The Hold traversing job is specifically
– caused by
– indicated by feedback bit
STOP by run command 6 or 7
"READY" after stop
"Motor running" is removed
STOPP by digital input DIS
" DIS input active "
Limit switch position reached
"Hardware limit switch reached "
"Travel range" exceeded
"Software limit switch reached"
8.3.2 Hold Traversing job in Exceptional Cases
In the following cases, the traversing job is stopped with loss of synchronisation:
Incorrect operation of the control interface during a traversing job
Voltage loss of the IM
CPU loss
Station stop
Impacts
If one of the reasons for stopping the current positioning occurs, it is terminated by a de-
celeration ramp.
The feedback value is also updated when the transport order is stopped in exceptional
cases. This allows you to move a remaining distance after stopping through a new travers-
ing job in the "relative positioning" operating mode.
i
When stopping during the acceleration phase, the TM StepDrive emits pulses for a
maximum of 50 ms at the frequency already reached before initiating the decelera-
tion process. This avoids abrupt frequency changes that could lead to step losses.
Содержание TM StepDrive 1x24..48V/5A
Страница 11: ...Technology Module TM StepDrive 1x24 48V 5A MA 1303 A007 EN 10 1 5 Declaration of Conformity...
Страница 51: ...Technology Module TM StepDrive 1x24 48V 5A MA 1303 A007 EN 50...
Страница 77: ...Technology Module TM StepDrive 1x24 48V 5A MA 1303 A007 EN 76...
Страница 92: ...Phytron GmbH Industriestra e 12 82194 Gr benzell T 49 8142 503 0 F 49 8142 503 190 www phytron eu...