"Referencing with Offset" = 0 and "Referencing to reference sensor" = 1
Fig. 15: Reference point approach, M0P
reference sensor
"Referencing with Offset" = 1 and "Referencing to reference sensor" = 1 in pos. di-
rection, start position is to the right of the reference signal
Fig. 16: Reference point approach, M0P
reference offset in positive direction
"Referencing with Offset" = 1 and "Referencing to reference sensor" = 1 in pos. di-
rection, start position is to the left of the reference signal
If the reference sensor is detected before the limit switch, it is immediately moved freely:
Fig. 17: Reference point approach, M0P
reference offset in positive direction
i
If a traverse range is parameterised and a switch is not found within this range,
the reference point search is aborted with "Positioning error".