phytron
35
MA 1303-A007 EN
6.2 Configuration of the Module Using the GSD Description File
The resolution of the current settings is reduced, because in the GSD format only a small
amount of data is available on the PROFIBUS.
The resulting current is shown in the following table:
Bit value
Current [A]
Bit value
Current [A]
0x00
0.0
0x10
1.6
0x01
0.1
0x11
1.7
0x02
0.2
0x12
1.8
0x03
0.3
0x13
1.9
0x04
0.4
0x14
2.0
0x05
0.5
0x15
2.1
0x06
0.6
0x16
2.2
0x07
0.7
0x17
2.3
0x08
0.8
0x18
2.4
0x09
0.9
0x19
2.5
0x0A
1.0
0x1A
2.6
0x0B
1.1
0x1B
2.8
0x0C
1.2
0x1C
3.0
0x0D
1.3
0x1D
3.2
0x0E
1.4
0x1E
3.3
0x0F
1.5
0x1F
3.5
i
If the full resolution is required, the DS128 can be set in 100 mA increments.
Содержание TM StepDrive 1x24..48V/5A
Страница 11: ...Technology Module TM StepDrive 1x24 48V 5A MA 1303 A007 EN 10 1 5 Declaration of Conformity...
Страница 51: ...Technology Module TM StepDrive 1x24 48V 5A MA 1303 A007 EN 50...
Страница 77: ...Technology Module TM StepDrive 1x24 48V 5A MA 1303 A007 EN 76...
Страница 92: ...Phytron GmbH Industriestra e 12 82194 Gr benzell T 49 8142 503 0 F 49 8142 503 190 www phytron eu...