Technology Module TM StepDrive 1x24..48V/5A
MA 1303-A007 EN
56
7.2.2 Feedback Value
Depending on the setting in byte 5 of the control interface, either nothing is displayed here
or the remaining distance to be travelled or the current frequency is displayed when posi-
tioning (data type 32 Bit, DEZ+/-, address ID4).
The data from the control interface and feedback interface can be transmitted clock-
synchronously (isochronously).
However, this does not mean that, for example, if a new frequency value is specified, it will
immediately be visible in the feedback interface. The value in the feedback interface corre-
sponds to the frequency currently output by the motor controller.
7.2.3 Set Feedback Value
Here, the setting of byte 5 of the control interface is displayed (data type 8 Bit, DEZ, ad-
dress IB8).
7.2.4 Feedback Bits in Byte 9 ...11
Bit
Name
Meaning
I9.0
Input 3
is active, when input 3 is in the active status.
I9.1
Input 2
is active, when input 2 is in the active status.
I9.2
Input 1
is active, when input 1 is in the active status.
I9.3
Reference
search suc-
cessfully
completed
is set, if the zero point of the axis was found during a ref-
erence run.
I9.4
Reference
search is
executed
is set while the axis is executing a reference run
I9.5
deactivated
is set, when the power stage does not supply the motor
with current.
I9.6
Ramp
is set, when the motor accelerates or brakes.
I9.7
Motor is run-
ning
is set, when the motor is running and
is reset, when the motor is stopped.
Содержание TM StepDrive 1x24..48V/5A
Страница 11: ...Technology Module TM StepDrive 1x24 48V 5A MA 1303 A007 EN 10 1 5 Declaration of Conformity...
Страница 51: ...Technology Module TM StepDrive 1x24 48V 5A MA 1303 A007 EN 50...
Страница 77: ...Technology Module TM StepDrive 1x24 48V 5A MA 1303 A007 EN 76...
Страница 92: ...Phytron GmbH Industriestra e 12 82194 Gr benzell T 49 8142 503 0 F 49 8142 503 190 www phytron eu...