Technology Module TM StepDrive 1x24..48V/5A
MA 1303-A007 EN
46
6.5.5.2 Run Current
Here, the motor current during run is defined.
Value adjustable (in 100 mA increments):
0 = not allowed
1 = 0.1 A
r.m.s.
35 = 3.5 A
r.m.s.
6.5.5.3 Stop Current
Here, the motor current is defined, to which is switched after the lapse of the current delay
time as soon as the motor is stopped.
Value adjustable (in 100 mA increments):
0 = allowed
1 = 0.1 A
r.m.s
35 = 3.5 A
r.m.s
6.5.5.4 Boost Current (in PM mode only)
This parameter defines the motor current during acceleration and braking processes if
boost is activated.
Value adjustable (in 100 mA increments):
0 = allowed
1 = 0.1 A
r.m.s
35 = 3.5 A
r.m.s.
6.5.5.5 Current Delay Time
This parameter defines the time until switching from run current to stop current after motor
stop. The parameter should be adjusted to the minimum run velocity.
Value adjustable:
0: 1 ms
1: 2 ms
2: 4 ms
3: 6 ms
4: 8 ms
5: 10 ms
6: 12 ms
7: 14 ms
8: 16 ms
9: 20 ms