IC-05 Card Capture Reader 

17 

 

Figure 8. Diagram for connecting the card capture reader to the ACS-controller  

 via Wiegand interface

 1

 

                                            

1

 The list indicated elements is given in the Table 2. 

Содержание IC-05

Страница 1: ...Card Capture Reader IC 05 ASSEMBLY AND OPERATION MANUAL ...

Страница 2: ...Card Capture Reader IC 05 Assembly and Operation Manual ...

Страница 3: ...allation instructions 12 8 1 General recommendations 12 8 2 Installation tools 12 8 3 Cables parameters 13 8 4 Installation 13 8 5 Connection layouts 15 9 Operation instructions 18 9 1 Power up 18 9 2 Presenting an access card 18 9 2 1 Temporary guest card 18 9 2 2 Permanent card of staff 19 9 3 Blocking of card capturing when filling the card container 19 9 4 Removal and installation of the card ...

Страница 4: ...ntroller and blocking device OD turnstile swing gate door lock etc The card reader is installed inside of the card reader selection purchase and installation of the reader is performed directly by the customer installer When used in PERCo access control systems the data is transferred via RS 485 interface from built in reader of the card capture reader to the PERCo ACS controller The ability to op...

Страница 5: ...ion class III IEC 61140 Ingress Protection Rating IP41 EN 60529 Overall dimensions L W H see Fig 1 197 157 990 mm Weight net max 15 kg Attention This model of the card capture reader is not equipped with a built in card reader Selection of the reader and installation into the card capture reader is performed by the customer installer in accordance with the project of the checkpoint and the charact...

Страница 6: ...ntainer Card reader SXUFKDVHG separately is mounted under the cover of the card capture reader on a special bracket The identifier is read from the access card that is inserted in the slot of the card capture reader On the cover there is an indication module with mnemonic indicators as well as LED backlight of the slot for capturing cards The slot for card acceptance has a form that allows the car...

Страница 7: ...cover 3 card container 4 card container lock 5 slot for guest cards capture 6 base 10 cover fixing screws located under the container Not included in the standard delivery set 7 card capture reader power cable 8 cable for ACS controller connection 9 cable for connection of the card reader ...

Страница 8: ...nal blocks XT1 Capture card input of the card capture reader INPUT and GND contacts Withdrawal of a card that is inserted in the slot is performed when the control signal is sent from the output of the ACS controller to the input XT2 Card captured outputs of the card capture reader OUT and COM contacts and Alarm Alarm and COM contacts The Card captured control signal is sent by the card capture re...

Страница 9: ...e voltage at the open contact relates to GND 5 0 5 V the voltage at the closed contact in relation to GND not more than 0 8 V current through the closed contact not more than 1 5 mA Card captured and Alarm outputs contacts 1 and 2 of XT2 connector block type dry contact Each of these outputs represent one of the relay contacts The other contacts of both relays are combined together for COM output ...

Страница 10: ...ithm of the card capture reader doesn t depend on the type of interface used for data exchange between the reader of the card capture reader and the ACS controller 1 Initial state In the initial state Insert the card into the slot white indicator and blue LED are lit on the cover of the display unit 2 The presentation of the access card To present the card to the reader insert it in the slot 5 tha...

Страница 11: ...ure reader The container is filling as the cards are withdrawn The third optical sensor activates and LED backlight of the slot and switches to flash mode when the container is filled 2 seconds on 2 seconds off indication warns the operator that it is necessary to empty container from cards The Alarm control signal is formed at the output of the card capture reader control board which can be used ...

Страница 12: ...orks should be performed only with the power supply switched off from the AC mains only serviceable tools should be used for installation while the installation of the card capture reader until it is fixed be extra cautious and protect it from falling down before the first switching of the card capture reader make sure it is installed correctly Installation of the power supply unit should be done ...

Страница 13: ...ollow the instructions to the latter The card capture reader should be placed in front of the OD at the exit from the enterprise It is necessary to enable access to the container for operating personnel We recommend mount the card capture reader on flat solid concrete floors grade 400 or higher SCS B22 5 stone or similar foundations at least 150 mm thick use reinforcing elements 300 300 150 mm for...

Страница 14: ... min Cat5 2 2 0 52 F UTP2 Cat5e 4 Reader board ACS controller Wiegand 50 24AWG 18AWG 0 2 0 8 mm2 RAMCRO SA82BI T W8ekw CABS8 EC 8C SEC SC 8 4 Installation Further installation instructions are given with the earlier mentioned recommendations see Clause 8 1 taken into account Types of cables are stated in Table 1 Recommendations on preparation of mounting holes in the mounting surface are given wit...

Страница 15: ... separately on a special bracket under the cover of the card capture reader to provide reading of the access card that are inserted in the slot of the card capture reader mechanism Attention Built in reader should be purchased separately Inside the card capture reader it is possible to mount all PERCo readers It is also possible to mount the readers by third party manufacturers if they comply to t...

Страница 16: ...oller in accordance with the card capture reader operation algorithm see sect 5 4 and with the service documentation of the ACS controller 8 5 Connection layouts Figure 6 Diagram for connecting the card capture reader to the CT L 04 2 CT 03 2 controllers via the RS 485 interface 1 1 The list indicated elements is given in the Table 2 ...

Страница 17: ... passage permission directly from the control board of the turnstile In this case connect the turnstile CLB Board output XT5 Light B or XT4 Light A depending on the direction of the passage to the input of the card capture reader XT4 LED L or R contact Similarly you can connect a third party turnstile if its indication control output satisfies the parameters of the LED input see sect 5 3 1 The lis...

Страница 18: ...IC 05 Card Capture Reader 17 Figure 8 Diagram for connecting the card capture reader to the ACS controller via Wiegand interface 1 1 The list indicated elements is given in the Table 2 ...

Страница 19: ... its service documentation 2 Connect power supply unit to the mains with voltage and frequency given in its Certificate Switch on the power supply unit 3 The white indicator Insert the card into the slot and LED backlight of the slot will switch on the indication module 4 Check operation of the card capture reader together with the ACS controller in all modes according to the operation algorithm s...

Страница 20: ...n the container of the card capture reader is filled with withdrawn access cards the backlight of the slot will switch to a flashing mode 2 seconds on 2 seconds off This warning signal informs technicians that the container must be emptied from cards If the container is not empty then withdrawal of the access cards will be blocked after the card capture reader receives another 9 cards When the con...

Страница 21: ... room should be free from vapors of acids alkalis and gases that cause corrosion After transportation or storage at below zero temperatures or high air humidity the card capture reader should be kept unpacked for no less than 24 hours under normal climate conditions 11 TROUBLESHOOTING Possible faults to be corrected by the customers themselves are listed in Table 3 For faults not listed in Table 3...

Страница 22: ...anual 2 Go to Administration Configuration section by using the navigation bar 3 On the page working area select the main controller that is physically connected to the card capture reader 4 Click Edit button on the page toolbar The Device properties window will appear 5 In the appeared window select Additional outputs tab 6 In the window working area select Additional output number of the output ...

Страница 23: ...for the Type parameter set Disconnected value for the Normal state of the contact parameter set Device direction value for the Device number parameter the number of OD and direction number must match those that are controlled by the card capture reader 10 If necessary configure the system response to the Fault signal sent by the card capture reader To do this select Additional input number of the ...

Страница 24: ...own menu set Standard value for the Type parameter set Not energized value for the Normal state parameter 12 Click Save and close button The Device properties window will be closed 13 Within the main controller select the controller of the OD which is controlled by a card capture reader 14 Click Edit button on the page toolbar The Device properties window will appear 15 Switch to Reader tab number...

Страница 25: ...meter or respectively from the remote control When passing When passing with VIOLATED TIMING When passing with ZONALITY VIOLATION specify the desired value for the Waiting period for verification confirmation from the external verification device parameter or respectively from the remote control which will be used by the controller for waiting of a Card captured signal 17 Select the group of param...

Страница 26: ...ional outputs check Additional output 3 number of the output that is connected to the Capture card input of the card capture reader 18 In the left part of the tab select Withdraw the identificators of the visitors after the passage parameter and check the box ...

Страница 27: ...t basic algorithm of cards withdrawal by using the Web interface Advanced options are available in PERCo Web software CT L 04 CT 03 controllers don t support operation with the card capture reader via Web interface 1 In Configuration Edit Operating devices section select the OD that is physically connected to the card capture reader then select Reader 1 or Reader 2 depending on the direction of th...

Страница 28: ... Add the following Internal response in Configuration Edit Internal response section Source type Visitor ID card presentation Source number 1 number of OD that is physically connected to the card capture reader Source direction 1 or 2 depending on the passage direction that is controlled by the card capture reader Receiver type Activate output Receiver number 3 number of the output that is physica...

Страница 29: ...roller can be used for receiving the Alarm signal sent by the card capture reader It is necessary to set the type of response on the activation of this input for example blocking of the reader in the passage direction that is controlled by the card capture reader ...

Страница 30: ...nected to the LED input of the card capture reader Normal state Not energized Function Output Add the following Internal response in Configuration Edit Internal response section Source type Unblock device Source number 1 number of OD that is physically connected to the card capture reader Source direction 1 or 2 depending on the passage direction that is controlled by the card capture reader Recei...

Страница 31: ... and Physical contacts after configuration template Turnstile card capture reader controls the direction number 1 Input 6 and Output 3 are used to control the card capture reader Input 5 is used receive the Alarm signal Output 4 is used to control the indication of the card capture reader ...

Страница 32: ...access card that should be issued for a visitor and in the appeared window on the General tab select Temporary value for the Card type parameter then determine the period of validity of the card on the Access rights tab set the Yes value to Verification parameter for reader 1 or 2 depending on the direction of the passage is controlled by the card capture reader in this case the Status of this set...

Страница 33: ...PERCo Polytechnicheskaya str 4 block 2 194021 Saint Petersburg Russia Tel 7 812 247 04 64 E mail export perco com support perco com www perco com ...

Страница 34: ...www perco com ...

Отзывы: