![PERCo IC-05 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/perco/ic-05/ic-05_assembly-and-operation-manual_1528175017.webp)
Assembly and Operation Manual
16
Figure 7. Diagram for connecting the card capture reader to the CT/L-04, CT-03
controllers via the RS-485 interface
Attention!
If
PERCo
turnstile is used as an OD, then it is possible to control the indication of
passage permission directly from the control board of the turnstile. In this case,
connect the turnstile CLB Board output
XT5
,
"Light B"
(or
XT4
"Light A"
depending on
the direction of the passage) to the input of the card capture reader
XT4
"LED"
(
L
or
R
contact). Similarly, you can connect a third party turnstile, if its indication control output
satisfies the parameters of the
"LED"
input (see sect. 5.3).
1
The list indicated elements is given in the Table 2.