![PERCo IC-05 Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/perco/ic-05/ic-05_assembly-and-operation-manual_1528175014.webp)
IC-05 Card Capture Reader
13
8.3 Cables parameters
The cables used for connection of the card capture reader are given in Table 1.
Table 1. Recommended cable types
№
Connection
Max. length, m
Cable type
Example
1
IC-05
–
power supply
30
Twisted pair cable with
cross section min. 0.75 mm
2
AWG 18; HO3VV-F 2×0.75
bi-coloured
50
Twisted pair cable with
cross section min. 1.5 mm
2
AWG 15;
2×1.5 bi-coloured
2
IC-05
–
ACS-controller
50
24AWG – 18AWG
(0.2 – 0.8 mm
2
)
RAMCRO SA82BI-T, W8ekw
CABS8/EC, 8C.SEC-SC,
3
Reader board –
ACS-controller,
RS-485
50
Twisted pair cable, min.
Cat5
2×2×0.52, F/UTP2-Cat5e
4
Reader board –
ACS-controller,
Wiegand
50
24AWG – 18AWG
(0.2 – 0.8 mm
2
)
RAMCRO SA82BI-T, W8ekw
CABS8/EC, 8C.SEC-SC,
8.4 Installation
Further installation instructions are given with the earlier mentioned recommendations (see
Clause 8.1 taken into account. Types of cables are stated in Table 1.
Recommendations on preparation of mounting holes in the mounting surface are given
with regard to “SORMAT” PFG IR 10 anchor bolts for solid concrete floors.
Follow this sequence during reader installation:
1. Unpack the card capture reader, check the delivery set completeness.
2. Mark and prepare mounting holes for anchor bolt sleeves on the installation surface
according to Figure 5.
Figure 5. Hole pattern for mounting of the housing