Pulscon LTC57 PROFIBUS PA
Mounting
2015
-0
3
37
Mounting rope probes
Figure 6.20
When lowering the rope probe into the vessel, observe the following:
• Uncoil rope and lower it slowly and carefully into the vessel.
• Do not kink the rope.
• Avoid any backlash, since this might damage the probe or the vessel fittings.
Warning!
Electrostatic discharges may damage the electronics.
• Earth the housing before lowering the rope into the vessel.
Note!
Mounting rope probes in a partially full silo
It is not always possible to empty a silo which is already in operation. If a minimum of 2/3 of the
silo is empty, it is possible to install the probe into the partially filled silo. If possible, make a
visual check after the installation to see that the rope has not tangled or is lying such that it can
knot when the level falls. Before full accuracy is obtained the probe rope must hang fully
extended.