20
Pulscon LTC57 PROFIBUS PA
Mounting
6
Mounting
6.1
Mounting requirements
6.1.1
Suitable mounting position
Figure 6.1
Mounting requirements
Mounting distances
• Distance (A) between wall and rod or rope probe:
•
for smooth metallic walls: > 50 mm (2 in)
• for plastic walls: > 300 mm (12 in) to metallic parts outside the vessel
• for concrete walls: > 500 mm (20 in), otherwise the available measuring range may be
reduced.
• Distance (B) between rod or rope probe and internal fittings in the vessel: > 300 mm (12 in)
• Distance (C) from end of probe to bottom of the vessel:
•
Rope probe: > 150 mm (6 in)
• Rod probe: > 10 mm (0.4 in)