2000-A2-GB20-10
- 243 -
February 2004
ISDN-BRI
Diagnostics
Type
B
to perform BRI Diagnostics.
The IAD displays the BRI Diagnostics menu:
Figure 14–4. BRI Diagnostics Menu
Before conducting any test or enabling an option, type O to select the BRI
line to on which to operate (1-4).
Next, perform the test or enable/disable options by typing the option.
When testing is complete, type 8 to disable all test modes.
LAN LINK
LAN ACT
WAN LINK
VOICE
POWER
JF2004i
JF2104i
The BRI diagnostics menu for ISDN testing is available on the
two ISDN-based IADS; JF2004i and JF2104i.
************************************************
BRI Diagnostics Menu
***********************************************
0. Select BRI Line
1. Send D Channel Test Pattern
2. Enable Internal Digital Loop
3. Enable Internal Analog Loop
5. Enable Remote Loop
6. Enable SSP
7. Enable SCP
8. Disable All Test Modes
9. Send B1 Channel Test Pattern
A. Send B2 Channel Test Pattern
B. Enable/Disable BRI L1 debug message
C. Enable/Disable BRI Dch debug message
D. Disable BRI PS
E. Enable BRI PS
F. Activate L1
G. Deactivate L1
M. Manufacture Loop Back Test
N. Burning Loop Back Test