PVIQ™ CONNECTIVITY SYSTEM USER MANUAL V 1.0
86
Individual Port Security Policy Method
This method may be used for patch field teardown or when removing individual patch
cords from a patch field. This method is typically used when removing one or more
individual connections in the patch field.
Perform the following steps to remove cross-connections to a PViQ™ Connectivity
System patch field or between two PViQ™ Connectivity System patch fields.
1. Open a supported web browser. Enter the IP address of the PViQ™ Connectivity
System that the patch cord connection is being removed from.
NOTE: If you are connecting a cross-connect between two PViQ™ Connectivity
Systems, you only need to log into one of the systems with an end point on that
connection. The security policy will automatically span across the two systems when
the following steps are completed.
2.
The Login Page will appear. Enter the appropriate username and password.
The
Dashboard
page will appear.
3. Select the
Patching
tab. The
Patching
page will appear.
4. Select the panel from the
Select a Panel
pulldown menu.
5. Select the port on the panel that you want to disconnect from the
Port Number
pulldown menu.
6. Click on the
Clear Security Policy
button.
a. The LEDs above the ports that the patch cord is plugged into (on both
ends of the patch cord) will start flashing red.
b. The
Panel Mode
will change to
MAC
mode.
c. The panel(s) MAC LED will light green.
7. Disconnect the cross-connect patch cord at both ends in the patch field.
a. The port LED will extinguish once the cord is removed from the port.
b. The MAC LED will automatically turn off when both ends of the cord have
been removed.
c. The
Panel Mode
will change back to
Secure
mode.
d. All
Far End Status
will get cleared out.
8. The connection has been removed from the system(s) and all systems involved
with be left in secure mode.