Configuration
57
A l a r m s – D e f i n i t i o n
F i e l d D a t a
ID
Uniquely identifies the chosen source that will trigger the specified alarm by its ID number.
Camera = port number of camera connected to the controller card. I/O Port = port number of the
Input port that the external source is connected. RS232 = port number of the external source that
will be connected through the RS232 port. Vid Loss (port) = port number of the input port that
will be detecting video loss. Note: When the source type is Vid Loss (any), this selection is
unavailable since multiple ports on the system can serve as the source.
Acknowledge:
Mode
Determines whether a user must manually respond to an alarm when triggered or if an automatic
response is generated requiring no user intervention. Choose Manual, Auto, or Both.
Delay
Defines the delay in seconds when an alarm is in Auto Acknowledge mode before the alarm is
automatically acknowledged. (min:sec) Up to 59:59
On-Screen
Display
In the Text box enter the text that you want to appear on the screen when an alarm is triggered.
This text will be displayed on all of the monitors that are part of the actions you select on the
Actions tab.
Location
Practical name to help an administrator select an alarm by location. Alphanumeric.
Examples:
Main concourse, loading dock, boiler room.
Reset – Mode
Chooses the method by which the alarm will be reset. Manual, Auto, and Both are options.
Delay
Specify the amount of delay time prior to resetting the alarm using the mode selected. In Auto
mode, the reset delay is started after the alarm is acknowledged.