Appendix A
148
Specific Notification (Currently Not Supported)
This is the setup for a specific encoder or decoder that sends alarm notifications to
another device (except MPU955A).
When Alarm Notification is set up, it is not necessary to change these settings.
S P E C I F I C N O T I F I C A T I O N
F i e l d D a t a
Device ID
Description: GX device identifier is a local physical number that is uniquely identified within a
system domain. Its format is shown as below:
_ _ _ _ _ X X X
device id (by rotary SW of an encoder front panel)
X X X X X _ _ _
device type
Validation: Device type [0x0F000 encode, 0x1F000 decoder, other reserved]
Default Setting: 0x0F000XXX
XXX is the value registered in Address[SW1] of the previous page .
Note: See MPEG2 Encoder and MPEG2 Decoder Operating Instructions.
Sub Device
Classification
Description: Specifies a device classification of an encoder or a decoder.
Validation: 20 = camera of an encoder, 21 = encoder DSP of an encoder, 29 = a decoder
Default Setting: (None)
Sub Device ID
Description: GX sub device identifier is a local physical number that is uniquely identified
within the device. It also refers as a channel.
Validation: 0 - 3
Default Setting: (None)
Alarm TCP
Description: Specifies whether to use TCP for alarm notification.
Validation: 0 = Disable, 1 = Enable
Default Setting: (None)
Alarm TCP
Destination
Description: Specifies the destination for alarm notification using TCP.
Validation: 0 for WJ-MPU955A, 1 for other device. When this value is set to 1, Alarm TCP/ IP
address and Alarm TCP Port No. are effective.
Default Setting: (None)
Alarm TCP/IP
Address
Description: Specifies a destination IP address for TCP alarm notification. This setting is
effective only when Alarm TCP Destination is 1.
Validation: Dotted decimal format IP address - 0.0.0.0 to 255.255.255.255
Default Setting: (None)
Alarm TCP Port
No.
Description: Specifies a destination IP port for TCP alarm notification. This setting is effective
only when Alarm TCP Destination is 1.
Validation: hexadecimal numeral 0000 -FFFF
Default Setting: (None)
Alarm UDP
Description: Specifies whether to enable UDP for alarm notification
Validation: 0 = Disable, 1 = Enable
Default Setting: (None)
Alarm UDP
Destination
Description: Specifies the destination for alarm notification using UDP.
Validation: 0 for WJ-MPU955A, 1 for other device. When this value is set to 1, Alarm UDP IP
address and Alarm UDP Port No. are effective.
Default Setting: (None)