41
■
Site alarm
Select "On" or "Off" whether to validate or invalidate
the site alarm.
On:
Validates the site alarm.
Off:
Invalidates the site alarm.
Default:
Off
■
Port number(from camera to ND400)
Designate the port number to be used for receiving the
site alarm.
Default:
1818
■
Site alarm setup
[Rec. cam.]
Select a camera channel (Cam.1 - Cam.64, "--") used
for recording. When no camera channel is selected
("--"), recording will not be performed.
[Preset position]
Select a preset position (blank, 1-256) to which the
camera will move upon a reception of a site alarm.
When no position is entered (blank), the camera does
not move to any preset position.
Default:
blank
[Output terminal]
Select "On" or "Off" to determine whether or not to out-
put an alarm signal at an event occurrence.
Default:
On
Setup items
Site alarm
Configure the settings relating to event actions to be taken at a site alarm occurrence.
1
Click the [Event] button.
2
Click the [Site alarm] tab.
The "Site alarm" page will be displayed.
3
Configure each setting item.
Refer to "Setup items" mentioned below.
To display the setting page of the camera whose
camera number is not on the current page, click the
desired camera channel number range displayed
above the [Set] button.
When displaying other setting page of the camera
by clicking the camera channel number range above
the [Set] button, the settings edited on the currently
displayed setting page will be saved and applied.
4