17-12
Error
code
Message
Probable Cause
Remedy
W0160
Water circuit error
Received "Water circuit error" error
from welding machine.
W0170
Weld Error: Cooling water
circuit
Received "Cooling water circuit"
error from welding machine.
Check welding machine.
W0180
Weld Error: Gas pressure
reduction
Received "Gas pressure reduction"
error from welding machine.
Check gas pressure.
W0190
Weld Error: Temp Err
Received "Temp Err" error from
welding machine.
W0200
Weld Error: Wire feed
motor
Received "Wire feed motor" error
from welding machine.
W0210
Weld Error: External input 1
Received "External input 1" error
from welding machine.
W0220
Weld Error: External input 2
Received "External input 2" error
from welding machine.
W0230
Weld Error: Emergency
stop
Received "Emergency stop" error
from welding machine.
W0240
Weld Error: CPU error
Received "CPU error" error from
welding machine.
W0250
Weld Error: Memory error
Received "Memory error" error from
welding machine.
W0260
Weld Error: Wire feed
governor
Received "Wire feed governor" error
from welding machine.
W0270
Weld Error: Wire feed
encoder
Received "Wire feed encoder" error
from welding machine.
W0280
Weld Error: CT offset
Received "CT offset" error from
welding machine.
W0290
Weld Error: VT offset
Received "VT offset" error from
welding machine.
W0300
Weld Error: Start input
signal
Received "Start input signal" error
from welding machine.
W0310
Weld Error: Initial output
voltage
Received "Initial output voltage"
error from welding machine.
Check welding machine.
W0320
Weld Error: Please replace
the tip.
One of the tip change conditions is
satisfied.
Replace the tip with new one.
Then reset the value in the tip change
dialog box. (On the [View] menu, click
[Arc weld information] and [TIP
CHANGE] to display the dialog box.)
W0330
MIG/TIM Force error
MIG force unit does not respond.
Check if the connection to the power
source of the MIG force unit is correct.
W0331
MIG/TIG Force: Servo
power error
A wire feed command is executed
while MIG/TIG Force servo power is
OFF.
Check the MIG/TIG Force.
W0340
MIG/TIG Force count over
Deviation counter of MIG force
motor exceeds (which occurs when
some load is applied to the motor
while the motor is stopping.)
Or the error may occur if the motor is
pulled by the retracting wire when
the servo is turned off.
Specify and correct the cause of the
error.
W0350
MIG/TIG Force Wire
buckling
Overload is detected in the MIG
force wire feed system. (Most
probable cause is buckling of the
wire in the wire feed route.
Check the wire feed route and remove
the cause of the buckling.