16-5. Welding commands(GMAW and common use)
16-5-1. ADJRST
Format
ADJRST
Function
To reset welding process fine adjustment to default values.
Condition
Weld package.
Lock condition
Arc lock (Internal execution).
Syntax check
None.
Example
ADJRST
The same command in conventional models
ADJRST
Values to be reset are those changed from their default values using the following sequences.
BBKTIME FTTLVL HOTCUR HOTVLT IAC
IB2
INIT-IB INIT-IP I-PFALL
I-PRISE
ISC ISL1 ISL2 PFALL
P-HOTTM
PPEAK PRISE TSO
TSP
WIRSLDN
16-5-2. AMP
Format
AMP [Amperage]
Function
Welding current setting.
Amperage
Welding amperage [1 - 999] A
Condition
Weld package.
Lock condition
Arc lock (Internal execution, specify values).
Syntax check
None.
Example
Sets welding amperage to 200A.
AMP=200
The same command in
conventional models
AMP
16-5-3. ARC-OFF
Format
ARC-OFF [File name] RELEASE=[Table]
Function
It ends the welding operation
File name
Name of the weld end operation file.
Condition
Weld package.
Lock condition
Arc lock (Internal execution).
Syntax check
The specified file name does not exist.
Table
Table number to execute
automatic stick release. [0 - 5]
Input “0” for no stick release.
* Note)
As for built-in welding power source
controller, the table #6 and #7 are
available, which is to retract wire
automatically when the stick release
functions.
Example
Execute ArcEnd1 file to end welding operation.
ARC-OFF ArcEnd1
The same command in
conventional models
AES
16-5-4. ARC-ON
Format
ARC-ON [File name] RETRY=[Table]
Function
It starts welding operation
Specify the file name for a series of torch ON
operation which has been store in another file.
The sample file using file name ArcStart1-5 is
set at shipment.
File name
Name of the file for weld start
operation.
Condition
Weld package.
Lock condition
Arc lock (Internal execution).
Syntax check
The specified file name does not exist.
Table
Table number to execute arc retry.
[0 - 5]
Input “0” for no arc retry.
Example
Execute ArcStart1 file to terminate welding
operation. Do not apply the arc retry function.
ARC-OFF ArcStart1 RETRY=0
The same command in
conventional models
ASS