16-30
16-8. Weld commands
(
Powder plasma welding
)
16-8-1. ARC-SET_POWD
Format
ARC-SET_POWD Ib= [Base amp] Ip= [Peak amp] PF= [Powder] FRQ= [Freq] S= [Speed]
Function
It sets a powder plasma welding condition.
Condition
Base amp
Welding amperage or base
amperage at pulsed welding
[5 - 200] A
Lock condition
Arc lock (Internal execution).
Syntax check
None.
Peak amp
No designation at no-pulsed
welding.
Peak amperage at pulsed welding
[5 - 200] A
Powder
Powder feed [0, 14 - 100]
Freq
Pulse frequency [0.5 - 25.0] Hz
Example
Set the base amp to20A
、
the peak amp to 95A
、
the powder to 38
、
the pulse frequency to 6.0Hz
and the weld speed to 0.26m/min.
ARC-SET_POWD Ib=20 Ip=95 PF=38 FRQ=6.0
S=0.26
Speed
Weld speed [0.01 - 120.00] m/min
16-8-2. CARRYGAS
Format
CARRYGAS [ON/OFF]
Function
It turns on or off the carrier gas.
ON/OFF
Carrier gas control
Condition
Lock condition
Arc lock (Internal execution).
Syntax check
None.
Example
Turn on the carrier gas.
CARRYGAS ON
The same command in
conventional models
16-8-3. CRATER_POWD
Format
CRATER_POWD Ib= [Base amp] Ip= [Peak amp] PF= [Powder] FRQ= [Freq] T= [Time]
Function
It sets a crater filler welding condition.
Condition
Base amp
Welding amperage or base
amperage at pulsed welding
[5 - 200] A
Lock condition
Arc lock (Internal execution).
Syntax check
None.
Peak amp
No designation at no-pulsed
welding.
Peak amperage at pulsed welding
[5 - 200] A
Powder
Powder feed [0, 14 - 100]
Freq
Pulse frequency [0.5 - 25.0] Hz
Example
Set the base amperage to 15A, the peak
amperage to 75A, the powder to 38, the
frequency to 6.0Hz and the time to 0.50s.
CRATER_POWD Ib=15 Ip=75 PF=38 FRQ=6.0
T=0.50
Time
welding time
[
0.00 - 99.99
]
16-8-4. F-RANGE
Format
F-RANGE = [High / Low]
Function
It changes the frequency range.
High / Low
Frequency range selection
Condition
Lock condition
Arc lock (Internal execution).
Syntax check
None.
Example
Change the frequency range to the high.
F-RANGE High
The same command in