16-35
16-9-5. WFACC
Format
WFACC [Acceleration]
Function
It specifies acceleration time of wire feeding.
Acceleration
Acceleration time:
Condition
Using TIG-FORCE.
[0.10 – 0.99] s
Lock condition
Arc lock (Internal execution)
Syntax check
None.
Example
WFACC 0.5
16-9-6. WFDCC
Format
WFDCC [Deceleration]
Function
It specifies deceleration time of wire feeding.
Deceleration
Deceleration time:
Condition
Using MIG,MAG
、
TIG-FORCE.
[0.10 – 0.99] s
Lock condition
Arc lock (Internal execution)
Syntax check
None.
Example
WFDCC 0.5
16-9-7. WFEED
Format
WFEED [Condition]
Function
It starts or stops wire feeding.
Condition
Condition
Using MIG,MAG
、
TIG-FORCE.
Lock condition
Arc lock (Internal execution)
Syntax check
None.
Stop
: Stop
Forward on: Start wire feed to
forward direction.
Reverse on
: Start wire feed to
reverse direction.
Preset FWD
: Start forward wire
feed by preset amount with the
WFLENGTH command.
Preset RVS
: Start reverse wire
feed by preset amount with the
WFLENGTH command.
Example
WFEED Preset FWD
Note
Wire is fed with LOW speed when the feed speed is not specified.
16-9-8. WFSLDN
Format
WFSLD =[Speed] m/min
Function
It specifies wire feed speed from the arc start to
the arc generation.
Speed
Condition
Wire feed speed
Range: [0.1 – 2.5 m/min]
Lock condition
Arc lock (Internal execution)
Syntax check
None
Example
Set the wire feed speed at arc start to 1.5 m/min.
WFSLDN 1.5
The same command in
conventional models
Note
* Please refer to section “Input of sequence commands” in the operation manual (OM0205052JE) of
push pull welding torch (YT-MBT501T**/YT-BMT501Y**).