
16-21
16-5-28. P-HOTTM
Format
P-HOTTM [Value]
Function
It adjusts pulse hot time.
Value
Adjustment value [
−
10 -
+
10]
Condition
Lock condition
Arc lock (Internal execution).
Syntax check
None.
Example
Adjust the pulse hot time to +1.
P-HOTTM +1
The same command in
conventional models
16-5-29. PMODE
Format
PMODE [Mode]
Function
It sets pulse mode.
Mode
Condition
Weld package.
Pulse mode
[SOFT/HARD/HYBRID].
Lock condition
Arc lock (Internal execution).
Syntax check
None.
Example
Change pulse mode to “SOFT”.
PMODE SOFT
The same command in
conventional models
PMODE
16-5-30. PPEAK
Format
PPEAK [Value]
Function
It adjusts pulse peak time.
Value
Adjustment value [
−
50 -
+
50]
Condition
Lock condition
Arc lock (Internal execution).
Syntax check
None.
Example
Adjust the pulse peak time to +1.
PPEAK +1
The same command in
conventional models
16-5-31. PRISE
Format
PRISE [Adjustment value]
Function
It adjusts the pulse rise angle.
Value
Condition
Weld package.
Lock condition
Arc lock (Internal execution).
Syntax check
None.
Panasonic fully digital welding
power sources: [-50 - +50]
Other power sources: [-5 - +5]
Example
Adjust the pulse rise angle set value by +2.
PFALL +2
16-5-32. STICKCHK
Format
STICKCHK [ON/OFF]
Function
It starts or terminates the stick check operation.
ON/OFF
ON: to start the stick check.
Condition
Weld package.
OFF: to terminate the stick check.
Lock condition
Arc lock.
Syntax check
None.
Example
Do stick check.
STICKCHK ON
The same command in
conventional models
OUTB OPORT#211=*