94
English
Command transmission method
Transmit in the following command format
Transmitted data
Header
Data part
Last
terminal
symbol
Hash value
(see
“Connection
method”)
‘0’
0x30
‘0’
0x30
Control
command
(ASCII
character
string)
(CR)
0x0d
32 bytes
1 byte
1 byte Undefined 1 byte
Received data
Header
Data part
Last
terminal
symbol
‘0’
0x30
‘0’
0x30
Control
command
(ASCII
character
string)
(CR)
0x0d
1 byte
1 byte
Undefined
1 byte
Error response
Error message
Last
terminal
symbol
“ERR1”
: Undefined control
command
(CR)
0x0d
“ERR2”
: Out of parameter range
“ERR3”
: Busy status or
reception invalid period
“ERR4”
: Timeout or reception
invalid period
“ERR5”
: Wrong data length
“ERRA”
: Mismatching of
password
4 bytes
1 byte
Note
●
With some of the commands, a part of character
string of the transmitted data may not be included in
the received data.
●
Consult your local Panasonic dealer for detail
instructions on command usage.
For more details, visit the following web site.
https://panasonic.net/cns/prodisplays/
PJLink protocol
The unit’s Network function is compatible with PJLink
Class 1 and Class 2. The following operations can be
performed from a computer when PJLink protocol is
used.
●
Setting the Display
●
Querying the Display status
Supported commands
The commands to control the unit with PJLink protocol
are as follows.
Class Command
Control
1
POWR
Power control
0: Standby
1: Power On
1
POWR?
Power status query
0: Standby
1: Power On
1,2
INPT
Input switch
*
Refer to INST? parameters.
1,2
INPT?
Input switch query
*
Refer to INST? parameters.
1
AVMT
Shutter control
10: Picture On
(picture mute deactivated)
11: Picture Off
(picture on mute)
20: Audio On
(audio mute deactivated)
21: Audio Off
(audio on mute)
30: Shutter mode Off
(picture and audio mute
deactivated)
31: Shutter mode On
(picture and audio on
mute)
1
AVMT?
Shutter control query
11: Picture Off (picture on
mute)
21: Audio Off (audio on mute)
30: Shutter mode Off
(picture and audio mute
deactivated)
31: Shutter mode On
(picture and audio on
mute)